Optimized Voltammetric Experiment for the Determination of Phloroglucinol at Surfactant Modified Carbon Nanotube Paste Electrode

Girish Tigari,J. G. Manjunatha
DOI: https://doi.org/10.1134/S0020441220050139
2020-09-24
Instruments and Experimental Techniques
Abstract:Present work describes the electrochemical sensing and determination of phenolic compound (Phloroglucinol) using non-ionic surfactant Octyl phenol ethoxylate modified carbon nanotube paste electrode (OPEMCNTPE) in PBS (0.1 mol, pH 6.0) by Voltammetric method. The developed electrode was characterized by field emission scanning electron microscope (FE-SEM) and cyclic voltammetric (CV) studies. The OPEMCNTPE shows an exceptional catalytic impact towards the electro-oxidation of Phloroglucinol (PL) in contrast to the bare carbon nanotube paste electrode (BCNTPE). The rise in the concentration of PL is directly proportional to PL anodic peak current in the linear working range 10–90 μmol with a small detection limit (LOD) 0.71 μmol. This method was utilized for the estimation of PL in the water and blood serum samples.
engineering, multidisciplinary,instruments & instrumentation
What problem does this paper attempt to address?