Temperature Regulation Model and Experimental Study of Compressed Air Energy Storage Cavern Heat Exchange System

Peng Li,Zongguang Chen,Xuezhi Zhou,Haisheng Chen,Zhi Wang
DOI: https://doi.org/10.3390/su14116788
IF: 3.9
2022-06-02
Sustainability
Abstract:The first hard rock shallow-lined underground CAES cavern in China has been excavated to conduct a thermodynamic process and heat exchange system for practice. The thermodynamic equations for the solid and air region are compiled into the fluent two-dimensional axisymmetric model through user-defined functions. The temperature regulation model and experimental study results show that the charging time determines the air temperature and fluctuates dramatically under different charging flow rates. The average air temperature increases with increasing charging flow and decreasing charging time, fluctuating between 62.5 °C and −40.4 °C during the charging and discharging processes. The temperature would reach above 40 °C within the first 40 min of the initial pressurization stage, and the humidity decreases rapidly within a short time. The use of the heat exchange system can effectively control the cavern temperature within a small range (20–40 °C). The temperature rises and regularly falls with the control system's switch. An inverse relationship between the temperature and humidity and water vapor can be seen in the first hour of the initial discharging. The maximum noise is 92 and 87 decibels in the deflation process.
environmental sciences,environmental studies,green & sustainable science & technology
What problem does this paper attempt to address?