A novel testing and theoretical approach for air-source heat-pump water heater with flash tank vapor-injection

Liu Xianglong,Hu Guang,Zeng Zhi,Wang Ping,Zeng Liping,Li Xiaohua
DOI: https://doi.org/10.1088/2631-8695/aca6cf
IF: 1.7
2022-11-30
Engineering Research Express
Abstract:Air-source heat-pump (ASHP) water heater provides an important low-carbon solution for domestic water heating, which regains the interest under the context of pursuing global carbon neutrality. In this study, a novel experimental and theoretical approach is proposed for ASHP water heater with flash tank vapor-injection by retrofitting the testing methods of state points. Five flash tank vapor-injections with different temperature levels were tested and verified the experimental method for ASHP water heater. On this basis of the tested compressor suction temperature, exhaust temperature, electronic expansion valve pre-throttle temperature, electronic expansion valve throttling temperature and vapor-injection temperature, a thermodynamic analysis was conducted to determine the system performances. The relationship between the vapor-injection pressure ratio, system heating capacity and COP was identified by adjusting the expansion valve opening degree of the system. The results show that the COP of the system first decrease and subsequently increase with the increase in vapor-injection pressure ratio, and the minimum COP appears when the vapor-injection pressure ratio is 0.3. This study provides new insights into the advanced ASHP water heater.
What problem does this paper attempt to address?