Point-of-care ultrasonography for diagnosing thoracoabdominal injuries in patients with blunt trauma.

Dirk Stengel,Johannes Leisterer,Paula Ferrada,Axel Ekkernkamp,Sven Mutze,Alexander Hoenning
DOI: https://doi.org/10.1002/14651858.CD012669.pub2
IF: 8.4
2019-10-04
Cochrane Database of Systematic Reviews
Abstract:Point-of-care sonography (POCS) has emerged as the screening modality of choice for suspected body trauma in many emergency departments worldwide. Its best known application is FAST (focused abdominal sonography for trauma). The technology is almost ubiquitously available, can be performed during resuscitation, and does not expose patients or staff to radiation. While many authors have stressed the high specificity of POCS, its sensitivity varied markedly across studies. This review aimed to compile the current best evidence about the diagnostic accuracy of POCS imaging protocols in the setting of blunt thoracoabdominal trauma.
medicine, general & internal
What problem does this paper attempt to address?