Abstract 12453: Tricuspid Regurgitation After ICD Implantation is Rather Due to the Transvenous Lead Than Natural Progression

Karel T BreemanAnnelot J Peijsterrianne A de Bruin-bonShari PepplinkhuizenWilleke Van Der StuijtJolien A De VeldNiek E BeurskensMartijn M StuiverArthur A WildeFleur V TjongReinoud E KnopsDept of Cardiology,Amsterdam UMC location Univ of Amsterdam,Amsterdam,NetherlandsDept of Epidemiology and Data Science,Amsterdam UMC location Univ of Amsterdam,Amsterdam,Netherlands
DOI: https://doi.org/10.1161/circ.146.suppl_1.12453
IF: 37.8
2022-11-01
Circulation
Abstract:Circulation, Volume 146, Issue Suppl_1, Page A12453-A12453, November 8, 2022. Introduction:Transvenous implantable cardioverter-defibrillators (TV-ICDs) are associated with greater tricuspid regurgitation (TR) severity, which leads to increased mortality. The pathophysiology is often assumed to be lead-related, hence, treatment includes lead extraction and alternative defibrillation strategies. However, TR may also be naturally occurring in the ICD population with a high risk of secondary TR, or may be caused by right ventricular pacing.Purpose:We aimed to evaluate the effect of ICD type (with or without lead) and pacing percentage on post-implantation TR severity.Methods:In this retrospective cohort study, we included consecutive patients with a first S-ICD or TV-ICD implantation between December 2009 until December 2019 and who underwent an echocardiography study ≤3 months before and ≤3 years post-implantation. TR severity at follow-up was adjusted for potential confounders using ordinal regression analysis.Results:118 patients were included (mean age 52±21; 29% female), of whom 31 (26%) with an S-ICD and 87 (74%) with a TV-ICD. Follow-up echocardiography was performed median 20 months (IQR 14-29 months) after implantation. Worsening TR between pre- and post-implantation echocardiography was found in 11/31 (34%) patients with an S-ICD and 45/87 (52%) patients with a TV-ICD (p=0.15). Adjusted for age, atrial fibrillation, baseline TR and mitral regurgitation, ventricular pacing percentage and time since ICD implantation, TV-ICDs were significantly associated with greater TR severity at follow-up (OR 8.38, p=0.002). Ventricular pacing percentage was very low (5/118 [4%] were paced >10%), and not significantly associated with greater TR severity (OR 0.97, p=0.123).Conclusions:Our results suggest that greater TR severity in ICD patients is mainly caused by the transvenous lead, rather than natural progression in the ICD population.
cardiac & cardiovascular systems,peripheral vascular disease
What problem does this paper attempt to address?