Micro‐galvanic corrosion of duplex stainless steel annealed at different temperatures evaluated by experiments and a numerical simulation model

Xinfeng Cao,Xiaojun Hu
DOI: https://doi.org/10.1002/maco.202213297
2022-08-05
Materials and Corrosion
Abstract:The micro‐galvanic corrosion of 2205 duplex stainless steel annealed at different temperatures is investigated through a numerical simulation model and immersion experiments. The simulation results are in good agreement with the immersion experimental results. The minimum value of the micro‐galvanic corrosion depth occurs when the annealing temperature is 1100°C. In this study, micro‐galvanic corrosion of SAF 2205 duplex stainless steel (DSS) annealed at different temperatures with different phase ratios (α/γ) in a 1 M H2SO4 + 1 M NaCl solution is analyzed by zero resistance ammeter (ZRA), immersion and numerical simulation model. COMSOL Multiphysics is used to solve the numerical simulation model and predict the local current density, potential distribution, and morphology of DSS annealed at different temperatures with different phase ratios. The modeling results are in good agreement with the immersion test results, which indicate that the micro‐galvanic corrosion depth of SAF 2205 DSS annealed at different temperatures initially decreases and then increases with the increase in the phase ratios (α/γ). The best micro‐galvanic corrosion resistance is obtained at an annealing temperature of 1100°C.
What problem does this paper attempt to address?