Design and Operating Characteristics Analysis of HTS Magnets for Dipole-Type DC Induction Heating
Xing Wang,Shaotao Dai,Tao Ma,Guozhong Jiang
DOI: https://doi.org/10.1007/s10948-023-06683-5
2024-01-11
Journal of Superconductivity and Novel Magnetism
Abstract:High-temperature superconducting (HTS) DC induction heating technology has the advantage of high heating efficiency, no harmonic pollution, uniform heating, etc., which is much better than the traditional AC induction heating technology in industrial heating applications. A dipole-type HTS DC induction heater is proposed in this paper, and the operating characteristics of the HTS magnet are analyzed. The HTS magnet consists of a dipole iron core, two racetrack coils wound with YBCO tapes, and a liquid nitrogen cryostat. Two racetrack coils are installed in the two iron yokes, and the magnetic field is generated in the air gap between the two iron yokes. When induction heating, the object to be heated is placed in this air gap and rotated, which in turn generates eddy currents and then heats. The HTS magnet is cooled by liquid nitrogen, and a DC magnetic field is generated by the HTS magnet in the air gap in the iron core. The critical current of the used YBCO tape is larger than 140 A at 77 K, self-field, and the tested critical current of the coil is 70 A. The testing results show that the axial magnetic flux density at the iron core air gap is 156 mT while the operating current of the coil is 60 A, which is consistent with the simulation results.
physics, condensed matter, applied