Restorative angle of zirconia restorations cemented on non‐original titanium bases influences the initial marginal bone loss: 5‐year results of a prospective cohort study

Franz J. Strauss,Marina Siegenthaler,Christoph H. F. Hämmerle,Irena Sailer,Ronald E. Jung,Daniel S. Thoma
DOI: https://doi.org/10.1111/clr.13954
2022-05-18
Clinical Oral Implants Research
Abstract:Aim To assess radiographic, restorative, clinical and technical outcomes as well as patient satisfaction of directly veneered zirconia restorations cemented on non‐original titanium bases over 5 years. Material and Methods Twenty‐four patients with a single missing tooth in the aesthetic zone were recruited. All patients received a two‐piece implant with a screw‐retained veneered zirconia restoration cemented extraorally on a titanium base abutment. Marginal bone levels (MBL), marginal bone changes, technical complications, patient satisfaction and clinical parameters including probing depth, bleeding on probing and plaque index were assessed at crown delivery (baseline), at one year (FU‐1) and five years (FU‐5) of follow‐up. To investigate the relationship between restorative angle and MBL as well as marginal bone changes (bone loss/bone gain), correlation tests and linear regression models were carried out. Results Twenty‐two patients were available for re‐examination at 5 years. The mean MBL amounted to 0.54±0.39 mm at baseline, and to 0.24±0.35 at FU‐5 (=bone gain) (p<0.001). At FU‐1, a positive correlation (r=0.5) between the mesial restorative angle and mesial MBL was found (p=0.012). Marginal bone changes between baseline and FU‐1 at mesial sites were also positively correlated with the mesial restorative angle (r=0.5; p=0.037). Linear and logistic regression models confirmed that mesial marginal bone loss was significantly associated with the mesial restorative angle at FU‐1 (p 0.05). At distal sites no correlations or associations between the restorative angle and MBL or marginal bone changes were found regardless of the time point. During the 5‐year follow‐up, 5 technical complications occurred, mainly within the first year and mostly chippings. All patients were entirely satisfied with their implant‐supported restoration at 5 years. Conclusion Within the limitations of the present study, the restorative angle of implant‐supported crowns on non‐original titanium bases might influence the initial marginal bone loss but without affecting their favourable long‐term clinical performance. A restorative angle of <40° may limit the initial marginal bone loss at implant‐supported crowns with titanium bases.
engineering, biomedical,dentistry, oral surgery & medicine
What problem does this paper attempt to address?