Zinc porphyrin/MXene hybrids with phosphate-induced stimuli-responsive behavior for dual-mode fluorescent/electrochemiluminescent ratiometric biosensing
Huayue Sun,Jing Guan,Huining Chai,Kun Yu,Lijun Qu,Xueji Zhang,Guangyao Zhang
DOI: https://doi.org/10.1016/j.bios.2024.116080
IF: 12.545
2024-05-01
Biosensors and Bioelectronics
Abstract:Highly sensitive ratiometric biosensors have attracted much attention in biomarker detection, but most rely on single-mode signals, which can affect accuracy. The development of new principles and methods for dual-mode ratiometric sensing can enhance detection accuracy. Herein, the zinc(II) meso-tetra(4-carboxyphenyl) porphyrin/MXene (ZnTCPP/Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>) hybrids with phosphate-induced stimuli-responsive behavior are used to develop a novel dual-mode fluorescent/electrochemiluminescent (FL/ECL) ratiometric biosensor. The composites exhibit FL quenching and enhanced ECL behavior involving dissolved O<sub>2</sub>. The FL quenching of ZnTCPP/Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> is caused by energy transfer (EnT) and photo-induced electron transfer (PET) from ZnTCPP to Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>. While the introduction of MXene compensates for the inadequate conductivity of ZnTCPP, facilitating electron transfer, which further makes the surface ZnTCPP more capable of activating O<sub>2</sub> to produce singlet oxygen (<sup>1</sup>O<sub>2</sub>), thereby generating enhanced cathodic ECL. Furthermore, phosphate ions (PO<sub>4</sub><sup>3-</sup>) can interact with the Ti sites of ZnTCPP/Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>, leading to competition for coordination with ZnTCPP, which in turn detaches ZnTCPP, resulting in enhanced FL and reduced ECL. On the basis of the phosphate-induced stimuli-responsive behavior, the dual-mode FL/ECL ratiometric biosensing of alkaline phosphatase (ALP) is achieved through ALP-catalyzed production of PO<sub>4</sub><sup>3-</sup> cascade effect with ZnTCPP/Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub>. The linear detection range for ALP is 0.1-50 mU/mL, with a detection limit as low as 0.0083 mU/mL. This proposed ZnTCPP/Ti<sub>3</sub>C<sub>2</sub>T<sub>x</sub> composites with stimuli-responsive behavior is expected to provide new ideas for the development of high-sensitivity dual-mode ratiometric biosensors with promising applications in the precise detection of important biomarkers.
biotechnology & applied microbiology,biophysics,chemistry, analytical,electrochemistry,nanoscience & nanotechnology