High-efficiency contaminant removal from hospital wastewater by integrated electrocoagulation-membrane process

Daswara Djajasasmita,Sutrisno,Alfathah Bania Lubis,Danurrendra,Siska Telly Pratiwi,Ferry Rusgiyarto,Febrianto Adi Nugroho,Putu Teta Prihartini Aryanti,Iwan Darmawan Ma''mur
DOI: https://doi.org/10.1016/j.psep.2022.05.071
IF: 7.8
2022-08-01
Process Safety and Environmental Protection
Abstract:In this work, high removal of contaminants in hospital wastewater has been achieved using an integration of electrocoagulation (EC) with ultrafiltration (UF) and reverse osmosis (RO). In EC system, Al electrodes were arranged in a monopolar-parallel and bipolar configuration. There are two parameters studied in the EC system, i.e., the configuration of electrodes (2A-2C-2B and 4A-2C-2B) and current densities. The EC-UF system with a configuration of 4A-2 C-2B and a current density of 88.5 A.m−2 resulted in high removal of TSS, TDS, BOD, and COD by 95.12 %, 97.53 %, 95.18 %, and 97.88 %, respectively. The effluent quality of the EC-UF was improved by substituting UF with RO membrane. The TSS, TDS, BOD, and COD removal were enhanced to 97.64 %, 99.85 %, 97.88 %, and 98.38 %, respectively. The permeate flux decline in UF membrane system was 47.83 % during 60 min of filtration time due to cake layer fouling on the membrane surface, while in the RO membrane system was 29.49 %. Since the EC-UF and EC-RO showed high efficiency in contaminants removal, these configurations could be used as clean technology to produce clean water for water reuse purposes. At a wastewater capacity of 5 m3.day−1, the operating cost for the EC-UF system was 3.92 US$.m−3, while the EC-RO system was 4.02 US$.m−3. The increase of wastewater capacity to 50 m3.day−1 reduced the operating cost to 0.89 US$.m−3 for the EC-UF system and 0.93 US$.m−3 for the EC-RO system.
engineering, environmental, chemical
What problem does this paper attempt to address?