Reconstruction of scalar and vectorial components in X-ray dark-field tomography

Florian L. Bayer,Shiyang Hu,Andreas Maier,Thomas Weber,Gisela Anton,Thilo Michel,Christian P. Riess
DOI: https://doi.org/10.1073/pnas.1321080111
IF: 11.1
2014-08-18
Proceedings of the National Academy of Sciences
Abstract:Significance X-ray Talbot−Lau grating interferometry provides a differential phase contrast and a dark-field image containing scattering information. The dark-field image is sensitive to granular and fibrous microstructures with sizes in the range of the grating periods (circa 5 μm), much below the typical resolution of medical imaging techniques like angiography or fluoroscopy (circa 150 μm). Dark-field contrast is influenced by the orientation of the microstructure in the object. We present an approach to recover the local microstructure orientation in a tomographic 3D reconstruction. Per voxel, we quantitatively reconstruct the vector of the dominant local orientation and the amount of (an)isotropic scattering for relatively large samples using a standard medical X-ray setup. This is experimentally shown for various specimens exhibiting varying degrees of structural orderings.