Synchronized Operation of DSP-Based Generalized Impedance Controller With Variable-Speed Isolated SEIG for Novel Voltage and Frequency Control

P. J. Chauhan,J. K. Chatterjee,Haresh Bhere,B. V. Perumal,Dipankar Sarkar
DOI: https://doi.org/10.1109/tia.2014.2356642
IF: 4.079
2015-03-01
IEEE Transactions on Industry Applications
Abstract:In this paper, the performance of a novel two-loop control strategy for a three-phase self-excited induction generator (SEIG), used in wind/microhydro/biogas-based isolated generation schemes, is presented. The implementation of the grid-interactive synchronization of the generalized impedance controller (GIC), an impedance-controlled operation of pulse width modulation (PWM) voltage-source converter, with SEIG is described. The SEIG frequency is tracked using digital phase-locked loop implemented on a dSpace DSP platform. The open-loop SEIG-GIC system is experimentally analyzed for the sensitivity of the SEIG voltage and frequency to GIC modulation index $m$ and phase angle $\delta$. Based on this, a simple and practical control strategy with proportionalintegral (PI)-based voltage and frequency feedback loops is evolved for the regulation of the SEIG voltage and frequency. A novel design procedure for both the PI controllers for stable closed-loop operation is presented. The performance of the proposed closed-loop system is experimentally tested under speed and load perturbations.
engineering, electrical & electronic, multidisciplinary
What problem does this paper attempt to address?