Ag-Ni bimetallic film on CaF2 prism for high sensitive surface plasmon resonance sensor
Ananthan Nisha,Pandaram Maheswari,Santhanakumar Subanya,Ponnusamy Munusamy Anbarasan,Karuppaiya Balasundaram Rajesh,Zbigniew Jaroszewicz
DOI: https://doi.org/10.4302/plp.v13i3.1114
2021-09-30
Photonics Letters of Poland
Abstract:We present a surface plasmon resonance (SPR) structure based on Kretschmann configuration incorporating bimetallic layers of noble (Ag) and magnetic materials (Ni) over CaF2 prism. Extensive numerical analysis based on transfer matrix theory has been performed to characterize the sensor response considering sensitivity, full width at half maxima, and minimum reflection. Notably, the proposed structure, upon suitably optimizing the thickness of bimetallic layer provides consistent enhancement of sensitivity over other competitive SPR structures. Hence we believe that this proposed SPR sensor could find the new platform for the medical diagnosis, chemical examination and biological detection. Full Text: PDF ReferencesJ. Homola, S.S. Yee, G. Gauglitz, "Surface plasmon resonance sensor based on planar light pipe: theoretical optimization analysis", Sens. Actuators B Chem. 54, 3 (1999). CrossRef X.D. Hoa, A.G. Kirk, M. Tabrizian, "Towards integrated and sensitive surface plasmon resonance biosensors: A review of recent progress", Bioelectron, 23, 151 (2007). CrossRef Z. Lin, L. Jiang, L. Wu, J. Guo, X. Dai, Y. Xiang, D. Fan, "Tuning and Sensitivity Enhancement of Surface Plasmon Resonance Biosensor With Graphene Covered Au-MoS 2-Au Films", IEEE Photonics J. 8(6), 4803308 (2016). CrossRef T. Srivastava, R. Jha, R. Das, "High-Performance Bimetallic SPR Sensor Based on Periodic-Multilayer-Waveguides", IEEE Photonics Technol. Lett. 23(20), 1448 (2011). CrossRef P.K. Maharana, R. Jha, "Chalcogenide prism and graphene multilayer based surface plasmon resonance affinity biosensor for high performance", Sens. Actuators B Chem. 169, 161 (2012). CrossRef R. Verma, B.D. Gupta, R. Jha, "Sensitivity enhancement of a surface plasmon resonance based biomolecules sensor using graphene and silicon layers", Sens. Actuators B Chem. 160, 623 (2011). CrossRef I. Pockrand, "Surface plasma oscillations at silver surfaces with thin transparent and absorbing coatings", Surf. Sci. 72, 577 (1978). CrossRef R. Jha, A. Sharma, "High-performance sensor based on surface plasmon resonance with chalcogenide prism and aluminum for detection in infrared", Opt. Lett. 34(6), 749 (2009). CrossRef E.V. Alieva, V.N. Konopsky, "Biosensor based on surface plasmon interferometry independent on variations of liquid’s refraction index", Sens. Actuators B Chem. 99, 90 (2004). CrossRef S.A. Zynio, A. Samoylov, E. Surovtseva, V. Mirsky, Y. Shirshov, "Bimetallic Layers Increase Sensitivity of Affinity Sensors Based on Surface Plasmon Resonance", Sensors 2, 62 (2002). CrossRef S.Y. Wu, H.P. Ho, "Sensitivity improvement of the surface plasmon resonance optical sensor by using a gold-silver transducing layer", Proceedings IEEE Hong Kong Electron Devices Meeting 63 (2002). CrossRef B.H. Ong, X. Yuan, S. Tjin, J. Zhang, H. Ng, "Optimised film thickness for maximum evanescent field enhancement of a bimetallic film surface plasmon resonance biosensor", Sens. Actuators B Chem. 114, 1028 (2006). CrossRef B.H. Ong, X. Yuan, Y. Tan, R. Irawan, X. Fang, L. Zhang, S. Tjin, "Two-layered metallic film-induced surface plasmon polariton for fluorescence emission enhancement in on-chip waveguide", Lab Chip 7, 506 (2007). CrossRef X. Yuan, B. Ong, Y. Tan, D. Zhang, R. Irawan, S. Tjin, "Sensitivity–stability-optimized surface plasmon resonance sensing with double metal layers", J. Opt. A: Pure Appl. Opt. 8, 959, (2006). CrossRef M. Ghorbanpour, "A novel method for the production of highly adherent Au layers on glass substrates used in surface plasmon resonance analysis: substitution of Cr or Ti intermediate layers with Ag layer followed by an optimal annealing treatment", J. Nanostruct, 3, 309, (2013). CrossRef Y. Chen, R.S. Zheng, D.G. Zhang, Y.H. Lu, P. Wang, H. Ming, Z.F. Luo, Q. Kan, "Bimetallic chips for a surface plasmon resonance instrument", Appl. Opt. 50, 387 (2011). CrossRef N.H.T. Tran, B.T. Phan, W.J. Yoon, S. Khym, H. Ju, "Dielectric Metal-Based Multilayers for Surface Plasmon Resonance with Enhanced Quality Factor of the Plasmonic Waves", J. Electron. Mater. 46, 3654 (2017). CrossRef D. Nesterenko Z. Sekkat, "Resolution Estimation of the Au, Ag, Cu, and Al Single- and Double-Layer Surface Plasmon Sensors in the Ultraviolet, Visible, and Infrared Regions", Plasmonics 8, 1585 (2013). CrossRef M.A. Ordal, R.J. Bell, R.W. Alexander, L.L. Long, M.R. Querry, "Optical properties of fourteen metals in the infrared and far infrared: Al, Co, Cu, Au, Fe, Pb, Mo, Ni, Pd, Pt, Ag, Ti, V, and W.", Appl. Opt. 24, 4493 (1985). CrossRef H. Ehrenreich, H.R. Philipp, D.J. Olechna, "Optical Properties and Fermi Surface of Nickel", Phys. Rev. 31, 2469 (1963). CrossRef S. Shukla, N.K. Sharma, V. Sajal, "Theoretical Study of Surface Plasmon Resonance-based Fiber Optic Sensor Utilizing Cobalt and Nickel Films", Braz. J. Phys. 46, 288 (2016). CrossRef K. Shah, N.K. Sharma, AIP Conf. Proc. 2009, 020040 (2018). [23] G. AlaguVibisha, Jeeban Kumar Nayak, P. Maheswari, N. Priyadharsini, A. Nisha, Z. Jaroszewicz, K.B. Rajesh, "Sensitivity enhancement of surface plasmon resonance sensor using hybrid configuration of 2D materials over bimetallic layer of Cu–Ni", Opt. Commun. 463, 125337 (2020). CrossRef A. Nisha, P. Maheswari, P.M. Anbarasan, K.B. Rajesh, Z. Jaroszewicz, "Sensitivity enhancement of surface plasmon resonance sensor with 2D material covered noble and magnetic material (Ni)", Opt. Quantum Electron. 51, 19 (2019). CrossRef M.H.H. Hasib, J.N. Nur, C. Rizal, K.N. Shushama, "Improved Transition Metal Dichalcogenides-Based Surface Plasmon Resonance Biosensors", Condens.Matter 4, 49, (2019). CrossRef S. Herminjard, L. Sirigu, H. P. Herzig, E. Studemann, A. Crottini, J.P. Pellaux, T. Gresch, M. Fischer, J. Faist, "Surface Plasmon Resonance sensor showing enhanced sensitivity for CO2 detection in the mid-infrared range", Opt. Express 17, 293 (2009). CrossRef M. Wang, Y. Huo, S. Jiang, C. Zhang, C. Yang,T. Ning, X. Liu, C Li, W. Zhanga, B. Mana, "Theoretical design of a surface plasmon resonance sensor with high sensitivity and high resolution based on graphene–WS2 hybrid nanostructures and Au–Ag bimetallic film", RSC Adv. 7, 47177 (2017). CrossRef P.K. Maharana, P. Padhy, R. Jha, "On the Field Enhancement and Performance of an Ultra-Stable SPR Biosensor Based on Graphene", IEEE Photonics Technol. Lett. 25, 2156 (2013). CrossRef
English Else
What problem does this paper attempt to address?
-
Plasmonic Nano-Arrays for Ultrasensitive Bio-Sensing
Jing Jiang,Xinhao Wang,Shuang Li,Fei Ding,Nantao Li,Shaoyu Meng,Ruifan Li,Jia Qi,Qingjun Liu,Gang Logan Liu
DOI: https://doi.org/10.1515/nanoph-2018-0023
IF: 7.5
2018-01-01
Nanophotonics
Abstract:Surface plasmon resonance (SPR) and localized SPR (LSPR) effects have been shown as the principles of some highlysensitive sensors in recent decades. Due to the advances in nano-fabrication technology, the plasmon nano-array sensors based on SPR and LSPR phenomena have been widely used in chemical and bioloical analysis. Sensing with surface-enhanced field and sensing for refractive index changes are able to identify the analytes quantitatively and qualitatively. With the newly developed ultrasensitive plasmonic biosensors, platforms with excellent performance have been built for various biomedical applications, including point-of-care diagnosis and personalized medicine. In addition, flexible integration of plasmonics nano-arrays and combining them with electrochemical sensing have significantly enlarged the application scenarios of the plasmonic nano-array sensors, as well as improved the sensing accuracy.
-
Analysis of Graphene-Based Photonic Crystal Fiber Sensor Using Birefringence and Surface Plasmon Resonance
Xianchao Yang,Ying Lu,Baolin Liu,Jianquan Yao
DOI: https://doi.org/10.1007/s11468-016-0289-z
IF: 2.726
2016-06-20
Plasmonics
Abstract:We present and numerically characterize a photonic crystal fiber (PCF)-based surface plasmon resonance (SPR) sensor. By adjusting the air hole sizes of the PCF, the effective refractive index (RI) of core-guided mode can be tuned effectively and the sensor exhibits strong birefringence. Alternate holes coated with graphene-Ag bimetallic layers in the second layer are used as analyte channels, which can avoid adjacent interference and improve the signal to noise ratio (SNR). The graphene’s good features can not only solve the problem of silver oxidation but also increase the absorption of molecules. We theoretically analyze the influence of the air hole sizes of the PCF and the thicknesses of graphene layer and Ag layer on the performance of the designed sensor using wavelength and amplitude interrogations. The wavelength sensitivity we obtained is as high as 2520 nm/RIU with the resolution of 3.97 × 10−5 RIU, which can provide a reference for developing a high-sensitivity, real-time, fast-response, and distributed SPR sensor.
materials science, multidisciplinary,nanoscience & nanotechnology,chemistry, physical
-
MgF2–Au–MgF2-polydopamine Based Surface Plasmon Resonance Sensor and Its Application in Biomedical Systems
Zhiyi Liu,Qing Peng,Heng Shi,Shuqing Sun,Jun Guo,Xiaoxiao Wang,Le Liu,Yanhong Ji,Jihua Guo,Hui Ma,Yonghong He
DOI: https://doi.org/10.1039/c3ay41380b
IF: 3.1
2013-01-01
Analytical Methods
Abstract:We report a MgF2-Au-MgF2-polydopamine based surface plasmon resonance (SPR) sensor and its biomedical applications. The symmetrical MgF2-Au-MgF2 geometry induced a minimum loss of surface plasmons leading to, so far, the best refractive index resolution of 2.2 x 10(-8) refractive index units (RIU) in a glucose solution protocol. Meanwhile, a high detection performance could be maintained in the sensed medium with a refractive index ranging from 1.03 to 1.33 RIU. In order to solve the problem of surface functionalization on MgF2, which was thought to be inert, we managed to form adherent polydopamine films onto the MgF2-Au-MgF2 surface by dopamine self-polymerization, and found that secondary reactions could be used to create a variety of ad-layers for further biological uses. Finally, a model experiment on a chip detecting cellular mediators in human aqueous humor demonstrated the biomedical application of this system.
-
Surface plasmon resonance (SPR)-based biosensor using MXene as a BRE layer and magnesium oxide (MgO) as an adhesion layer
Akash Srivastava,Y. K. Prajapati
DOI: https://doi.org/10.1007/s10854-021-06436-x
2021-07-08
Abstract:<p class="a-plus-plus">In this paper, a plasmonic sensor consists of a bimetallic layer of Ag and Au, a nano-thin layer of two-dimensional material MXene and a thin layer of Magnesium oxide (MgO) is proposed to operate in a visible region. Using Kretschmann configuration-based structure and transfer matrix method, the change in the refractive index of liquid Biosample have been observed at a fixed incident wavelength. Using the distinctive properties of Ti<sub class="a-plus-plus">3</sub>C<sub class="a-plus-plus">2</sub>T<sub class="a-plus-plus"><em class="a-plus-plus">x</em></sub> MXene and MgO, we have investigated the performance of Surface Plasmon Resonance (SPR) biosensor. Significant performance parameters such as Sensitivity, Figure of Merit (FoM) and Detection Accuracy (DA) calculated for different cases to prove the capability of proposed sensing structure. We also compared the sensitivity and sharpness of SPR curve obtained when using conventional adhesion layers such as titanium (Ti), chromium (Cr), and tantalum (Ta). A detailed investigation is carried out to observe the role of polymer as an adhesion layer and its thickness impact on FoM and resonance angle sharpness. The concept of Long range SPR (LR-SPR) and Short range SPR (SR-SPR) are also discussed.</p>
-
Hybrid Structure–Based SPR Sensor for Chemical Sensing with Enhanced Sensitivity
Mohan Kumar Paswan,Rikmantra Basu
DOI: https://doi.org/10.1007/s11468-023-02020-7
IF: 2.726
2023-09-07
Plasmonics
Abstract:In this paper, we have proposed a new multilayer structure and investigated its performance as a chemical sensor utilizing surface plasmon resonance. Our proposed design consists of a black phosphorus layer sandwiched between a metal layer and a graphene layer, blue phosphorene/MoS 2 heterostructure layers placed over it, and the sensing layer containing the analyte placed on top. A CaF 2 prism in the Kretschmann configuration is employed to excite surface plasmon resonance (SPR), and the angle interrogation method is used for analysis. Sellmeier equations calculate the reflectivity and other parameters of the multilayer design. We also study the effect of the combination of BP and metal interlayer. Analysis of the proposed design shows significantly improved sensitivity compared to recent SPR-based sensors. In this paper, the sensitivity of 466°/RIU is obtained with silver metal, BP, graphene, and BlueP/MoS 2 layers SPR sensor.
materials science, multidisciplinary,nanoscience & nanotechnology,chemistry, physical
-
Sensitivity Enhancement of 2D Material-Based Surface Plasmon Resonance Sensor with an Al–Ni Bimetallic Structure
Miaosen Hu,Min Li,Ming-Yu Li,Xiaoyan Wen,Shuo Deng,Sisi Liu,Haifei Lu
DOI: https://doi.org/10.3390/s23031714
IF: 3.9
2023-02-04
Sensors
Abstract:In this paper, a variety of 2D materials on the surface plasmon resonance sensor based on Al–Ni bimetallic layer are compared. Simulation results indicate that lateral position shift, which is calculated according to the real and imaginary parts of the refractive index of material, can be used as an effective parameter to optimize the sensitivity. By using the parameters for optimizing the SPR structures, the results show that the multiple layer models of Al(40 nm)–Ni(22 nm)–black phosphorus (BP)(1 L) and Al(40 nm)–Ni(22 nm)–blue phosphorus (BlueP)/WS2(1 L) exhibit average angular sensitivities of 507.0 °/RIU and 466 °/RIU in the refractive index range of 1.330–1.335, and maximum sensitivity of 542 °/RIU and 489 °/RIU at the refractive index of 1.333, respectively. We expect more applications can be explored based on the highly sensitive SPR sensor in different fields of optical sensing.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
-
ZnO and Bi-metallic (Ag–Au) Layers Based Surface Plasmon Resonance (SPR) Biosensor with BaTiO3 and Graphene for Biosensing Applications
G. Singh,N. Mudgal,A. Saharia,Ankit Agarwal
DOI: https://doi.org/10.1080/03772063.2020.1844074
2020-11-12
Abstract:In this work, a novel design of Zinc Oxide (ZnO) and bi-metallic (Ag–Au) layers based surface plasmon resonance (SPR) biosensor with barium titanate (BaTiO3) and graphene is proposed. The proposed structure consists of SF10 glass prism, ZnO, Ag, Au, BaTiO3, and graphene as a top layer for biomolecules adsorption. Here, the performance of this structure is studied and analysed for sensitivity along with the accuracy of detection and quality parameter for the shift in refractive index (RI) from 1.33 (sensing medium) to 1.45 and our reported results show that addition of bimetallic (Ag–Au) layers along with BaTiO3, improve the sensitivity of the proposed structure to 14.85% for the same RI range compared to last reported MoS2-graphene-based SPR sensor. Here at maximum sensitivity is reported as 116.67 degree/RIU while the accuracy of detection and the quality parameter are obtained as 4.54 and 37.87 RIU−1 respectively. These high-performance parameters of the design make this structure suitable for biosensing applications.
Chemistry,Biology,Engineering,Materials Science
-
High Sensitivity Surface Plasmon Resonance Sensor Based on Periodic Multilayer Thin Films.
Haoyuan Cai,Shihan Shan,Xiaoping Wang
DOI: https://doi.org/10.3390/nano11123399
IF: 5.3
2021-01-01
Nanomaterials
Abstract:Surface plasmon resonance (SPR) biosensors consisting of alternate layers of silver (Ag) and TiO2 thin film have been proposed as a high sensitivity biosensor. The structure not only prevents the Ag film from oxidation, but also enhances the field inside the structure, thereby improving the performance of the sensor. Genetic algorithm (GA) was used to optimize the proposed structure and its maximum angular sensitivity was 384°/RIU (refractive index unit) at the refractive index environment of 1.3425, which is about 3.12 times that of the conventional Ag-based biosensor. A detailed discussion, based on the finite difference time domain (FDTD) method, revealed that an enhanced evanescent field at the top layer–analyte region results in the ultra-sensitivity characteristic. We expect that the proposed structure can be a suitable biosensor for chemical detection, clinical diagnostics, and biological examination.
-
Enhanced Stability in Surface Plasmon Resonance Sensor Using Prism Coupler Based on Au/Bi2O3 Bilayer Film
Chenghua Sui,Zhong Lu,Bo Yan,Gaoyao Wei
DOI: https://doi.org/10.19026/rjaset.5.4206
2013-01-01
Abstract:Surface Plasmon Resonance (SPR) sensing has become a comprehensive utilized technology for detection, measurement and analysis in a wide spectrum of fields, ranging from biotechnology, environmental monitoring to food and drug monitoring. In this study, Au/Bi 2O3 bilayer films with various layer thicknesses were deposited by thermal evaporation method on BK7 prism substrates and then post-annealing was conducted under ambient conditions. The adhesive strength of Au/Bi2O3 and Bi2O3/prism was measured with different layer thicknesses. Also, the SPR responses (reflectance vs. incident angle) were investigated as a function of the thickness of Bi2O3 layer in the Kretschmann geometry using ethanol as dielectric. The results indicate that the adhesive strength between Au and prism was improved more than 3 times by introducing the Bi 2O3 as buffer layer. And the SPR dips also demonstrate that SPR sensor based on Au/Bi 2O3 bilayer films is practical, although the height of SPR dip with about 6nm Bi2O3 is approximately 4 times weaker than that of monolayer Au and the width (defined as FWHM) broadens from 9° to 11°.
-
A High-Sensitivity SPR Sensor with Bimetal/Silicon/Two-Dimensional Material Structure: A Theoretical Analysis
Pengyu Zhang,Junxian Wang,Guoquan Chen,Jian Shen,Chaoyang Li,Tingting Tang
DOI: https://doi.org/10.3390/photonics8070270
IF: 2.536
2021-07-09
Photonics
Abstract:In this paper, we reported a theoretical study of a novel Surface plasmon resonance (SPR) biosensor composed of BK7 prism, gold (Au)/silver (Ag) bimetallic layer, silicon and two-dimensional (2D) materials. The bimetallic layer combines the advantages of Au and Ag and the high refractive index silicon layer enhances the electric field on the surface of the sensor, so that the sensor has a better overall performance in terms of sensitivity and figure of merit (FOM). Compared with ordinary dielectrics, 2D materials have excellent photoelectric properties, such as larger specific surface area, higher carrier density and stronger adsorption capacity, which improve the detection ability of the sensor. The sensitivity of the optimized sensor achieves 297.2°/RIU, 274°/RIU and 246°/RIU when the silicon layer is covered with graphene, MXene (Ti3T2Cx) and MoS2, respectively. Compared with the traditional SPR sensor, the sensitivity of the structure has been significantly improved, and its excellent performance has broad application prospects in biosensing and other fields.
optics
-
Optimized film thicknesses for maximum refractive index sensitivity and figure of merit of a bimetallic film surface plasmon resonance sensor
Jakub Chylek,Dalibor Ciprian,Petr Hlubina
DOI: https://doi.org/10.1140/epjp/s13360-023-04798-1
2024-01-04
The European Physical Journal Plus
Abstract:In this paper, a simple surface plasmon resonance (SPR) optical sensor with a bimetallic gold-silver film is proposed and its parameters are optimized based on reflectance spectra analysis. In comparison with most SPR sensors, which use single gold films, the evanescent field of this bimetallic configuration at the analyte–metal interface enables the sensing with substantially enhanced refractive index (RI) sensitivity and figure of merit (FOM). The proposed structure comprising a BK7 glass substrate, an adhesion layer of chromium, a gold-silver plasmonic layer, and a protective layer of silicon dioxide is employed in the Kretschmann configuration for liquid analyte sensing. In order to achieve the best sensing properties, the gold-silver layer thickness ratio is varied, and a thorough analysis of reflectance spectra is performed based on RI sensitivity and FOM. For this purpose, a liquid analyte of aqueous solutions of NaCl is employed for angles of incidence 63 and 64 , respectively. Moreover, based on the analysis, an optimized gold-silver layer thickness ratio is selected, and a sensitivity of 41,592 nm per RI unit (RIU) and FOM of 424 RIU are reached. The designed bimetallic SPR structure proves to be advantageous compared to single-gold-film structures employed for sensing applications.
physics, multidisciplinary
-
Sensitivity Enhancement of Surface Plasmon Resonance Biosensor with 2-D Franckeite Nanosheets
Bhishma Karki,Sandeep Sharma,Yadvendra Singh,Amrindra Pal
DOI: https://doi.org/10.1007/s11468-021-01495-6
IF: 2.726
2021-07-19
Plasmonics
Abstract:The sensitivity of a standard surface plasmon resonance (SPR) biosensor in angular interrogation is low. A unique 2-dimensional substantial heterostructure, franckeite/graphene layer, has been deposited over the metal surface to improve the sensitivity; moreover, the sensitivity is limited to a certain extent. A SPR biosensor based on modified Kretschmann configuration has been investigated, contain bimetallic layers of silver (Ag) and nickel (Ni). A layer of franckeite is sandwich in the metal layer. The proposed configuration has a maximum sensitivity of 352°/RIU, which is 80.80% higher than the conventional sensor. The franckeite is an air-stable 2-D material and has application in the chemical, biological, and medical fields.
materials science, multidisciplinary,nanoscience & nanotechnology,chemistry, physical
-
Sensitivity Enhancement of Hybrid Two-Dimensional Nanomaterials-Based Surface Plasmon Resonance Biosensor
Nurzad Zakirov,Shaodi Zhu,Aurélien Bruyant,Gilles Lérondel,Renaud Bachelot,Shuwen Zeng
DOI: https://doi.org/10.3390/bios12100810
2022-09-30
Abstract:In this work, we designed structures based on copper nanosubstrate with graphene and two-dimensional transition metal dichalcogenides (TMDC) in order to achieve an ultrasensitive surface plasmon resonance biosensor. This system contains seven components: SF11 triangular prism, BK-7 glass, Chromium (Cr) adhesion layer, thin copper film, layers of one of the types of transition metal dichalcogenides: MoS2, MoSe2, WS2 or WSe2 (defined as MX2), graphene, sensing layer with biomolecular analyte. Copper was chosen as a plasmonic material because it has a higher conductivity than gold which is commonly used in plasmonic sensors. Moreover, copper is a cheap and widespread material that is easy to produce on a large scale. We have carried out both theoretical and numerical sensitivity calculations of these kinds of structures using the Goos-Hänchen (GH) shift method. GH shift is lateral position displacement of the p-polarized reflected beam from a boundary of two media having different indices of refraction under total internal reflection condition and its value can be retrieved from the phase change of the beam. The SPR signal based on the GH shift is much more sensitive compared to other methods, including angular and wavelength scanning, due to much more abrupt phase change of the SPR reflected light than its intensity ones. By optimizing the parameters of the SPR sensing substrate, such as thickness of copper, number of layers of 2D materials and excitation wavelength, we theoretically showed an enhanced sensitivity with a detection limit 10-9 refractive index unit (RIU).
-
Design of a Surface Plasmon Resonance Sensor Based on Grating Connection
Jun Zhu,Liuli Qin,Shuxiang Song,Junwen Zhong,Siyuan Lin
DOI: https://doi.org/10.1007/s13320-015-0244-1
2015-01-01
Abstract:Nowdays, the study of measurement of the biological field focuses on the research of improving surface plasmon resonance (SPR) in the fields of integration and detection sensitivity. We designed a kind of grating connected surface plasmon resonance sensor. Theoretically, we analyzed the wave vector and the effective refractive index relations with the diffraction grating structure. Then we obtained the nanoparticles enhancement SPR structure with a resolution 10 times higher than that of traditional SPR sensors. Also, we used the finite-difference time-domain (FDTD) analysis and simulation which showed that it was obvious with coupling effect by the nanoparticles enhancement SPR structure that the reflectance spectral bandwidth results validated the structure significantly which improved the sensitivity. Experimental results showed that the dynamic response of the designed sensor reached 10 −6 RIU (refractive index unit). This study has the certain significance to long-distance and special sensing applications.
-
A Performance-Enhanced Bimetallic Chip for the Detection of Cadmium Ions with Surface Plasmon Resonance
Kai Pang,Wei Dong,Bing Zhang,Shuyue Zhan,Xiaoping Wang
DOI: https://doi.org/10.1007/s11468-015-0150-9
IF: 2.726
2015-01-01
Plasmonics
Abstract:We demonstrate that a designed bimetallic chip is capable of improving the performance of a surface plasmon resonance (SPR) sensor based on angular interrogation. Through a numerical simulation and a refractometry experiment, we prove that this bimetallic chip can effectively reduce the noise level by about a factor of 2 compared to the traditional SPR sensors that only use a single gold film. The bimetallic chip presents a lower refractive index resolution of 5.3 × 10−7 refractive index units. In addition, the enhancement of the electric field intensity at the surface of the configuration by a factor of 2 makes it possible to have a high sensitivity in a larger region, which promotes the biosensing applications of the chip. Through a simple and novel method for the detection of cadmium ions (Cd2+) based on the bimetallic configuration, a detection level for Cd2+ (0.01 μM or 1.12 ppb) can be realized, which compares favorably with similar studies.
-
Numerical Investigation on High-Performance Cu-Based Surface Plasmon Resonance Sensor for Biosensing Application
M. Muthumanikkam,Alagu Vibisha,Michael Cecil Lordwin Prabhakar,Ponnan Suresh,Karupiya Balasundaram Rajesh,Zbigniew Jaroszewicz,Rajan Jha,Myilsamy Muthumanicam
DOI: https://doi.org/10.3390/s23177495
IF: 3.9
2023-08-29
Sensors
Abstract:This numerical research presents a simple hybrid structure comprised of TiO2-Cu-BaTiO3 for a modified Kretschmann configuration that exhibits high sensitivity and high resolution for biosensing applications through an angular interrogation method. Recently, copper (Cu) emerged as an exceptional choice as a plasmonic metal for developing surface plasmon sensors (SPR) with high resolution as it yields finer, thinner SPR curves than Ag and Au. As copper is prone to oxidation, especially in ambient conditions, the proposed structure involves the utilization of barium titanate (BaTiO3) film as a protection layer that not only preserves Cu film from oxidizing but enhances the performance of the sensor to a great extent. Numerical results also show that the utilization of a thin adhesive layer of titanium dioxide (TiO2) between the prism base and Cu film not only induces strong interaction between them but also enhances the performance of the sensor. Such a configuration, upon suitable optimization of the thickness of each layer, is found to enhance sensitivity as high as 552°/RIU with a figure of merit (FOM) of 136.97 RIU−1. This suggested biosensor design with enhanced sensitivity is expected to enable long-term detection with greater accuracy and sensitivity even when using Cu as a plasmonic metal.
engineering, electrical & electronic,chemistry, analytical,instruments & instrumentation
-
Performance enhancement of surface plasmon resonance biosensor based on prism with Kretschmann configuration assisted by 2D materials
P. S. Pandey,S. Raghuwanshi,M. Kumar,Santosh Kumar,Rajesh Singh
DOI: https://doi.org/10.1117/12.2647948
2023-03-17
Abstract:This manuscript aims to analyze the effect of bariumtitanate (BaTiO3) and molybdenumdisulfide (MOS2) along with gold (Au) on the sensing application of surface plasmon resonance (SPR) biosensors. The proposed multilayer structure has a BK7 prism, a bimetallic layer of Au, BaTiO3, and a MOS2 layer. BaTiO3 and MOS2 layers are used to improve the biosensor performance parameters by the Kretschmann configuration. The proposed configuration has enhanced the performance over the conventional sensor. The performance parameters like full width half maximum (FWHM), detection accuracy, and detection accuracy have been analyzed. The suggested biosensor can detect a wide range of analytes with an extensive refractive index range. The proposed sensor can be used to analyze chemical and biological analytes.
Engineering,Materials Science
-
Dual BaTiO 3 layer-cavity assisted enhancement of copper-based surface plasmon resonance biosensor
Kaihua Wei,Xianglong Su,Jianxing Zheng,Shuang Liu,Bohuan Chen,Yan Guo
DOI: https://doi.org/10.1016/j.ijleo.2024.171612
IF: 3.1
2024-01-11
Optik
Abstract:Studies have shown that the two-dimensional transition metal dichalcogenides, graphene and MXene (Ti 3 C 2 T x ), and other materials not only can effectively improve the sensitivity of the surface plasmon resonance (SPR) biosensor but also reduce the detection accuracy. A SPR sensor based on dual barium titanate (BaTiO 3 ) layers forming Fabry-Pérot (F-P) cavity was proposed to achieve this goal. Specifically, we employed a copper/nickel (Cu/Ni) bimetal as the plasmonic metal, two layers of BaTiO 3 wrapped Cu/Ni bimetal to form a F-P cavity structure, and PMMA as the sensing layer. By optimizing the thickness of each film layer, the sensitivity reached 554.6 o/RIU, 6.2% higher than Cu/Ni/PMMA structure, and the corresponding full width at half maximum (FWHM) decreased by 15.4%. In addition, we used seven two-dimensional materials to replace PMMA but keeping other parameters unchanged, the obtained FWHM of the reflection spectrum was also reduced. These findings may benefit the application of the Fabry-Pérot cavity in biosensors and spectral modulation.
optics
-
Design and analysis of SPR-based refractive index sensor with enhanced sensitivity based on graphene/BP heterostructure
Shivangani,Anupam Sahu,Dharmendra Kumar,Brijesh Kumar,Sachin Kumar Gupta
DOI: https://doi.org/10.1007/s11082-024-06933-3
IF: 3
2024-07-19
Optical and Quantum Electronics
Abstract:In this article, we propose a novel surface plasmon resonance (SPR) sensor design with the combination of two-dimensional (2D) nanomaterials including copper, nickel, and graphene, along with a bonding layer of black phosphorous, to achieve significant enhancements in plasmonic performance. Theoretical analysis of the parameters has been performed using the Fresnel equations and Transfer Matrix method, based on the Kretschmann setup. For the CaF 2 Prism/Cu/Ni/Graphene/BP/Sensing-Medium configuration, the optimized performance parameters include an angular sensitivity of 410°/RIU, a detection accuracy of 0.33789 ° , a figure of merit (FOM) of 138.538 RIU/deg, and a limit of detection of 2.439 for the medium being sensed at 633 nm. The utilization of both graphene and BP proves advantageous in increasing the SPR sensor's sensitivity since BP and graphene possess stronger adsorption energy, making it a more suitable candidate for actively binding biomolecules. The proposed device showcases considerable potential for the detection of large-sized molecules such as secretary vesicles and lysosomes. The numerical simulation has been performed in the COMSOL Multiphysics and MATLAB environment.
engineering, electrical & electronic,optics,quantum science & technology
-
Sensitivity-Enhanced Surface Plasmon Resonance Sensor with Bimetal/ Tungsten Disulfide (WS2)/MXene (Ti3C2Tx) Hybrid Structure
Maryam Ghodrati,Ali Mir,Ali Farmani
DOI: https://doi.org/10.1007/s11468-022-01685-w
IF: 2.726
2022-06-27
Plasmonics
Abstract:This work aims at improving the sensitivity of a surface plasmon resonance (SPR) sensor with the BK7 prism, silver/gold (Ag/Au) bimetallic films, 2D materials tungsten disulfide (WS 2 ), and MXene (Ti 3 C 2 T x ) under angular interrogation technique. The proposed SPR sensor is a free space structure using the Kretschmann configuration to stimulate surface plasmons (SPs). The finite-difference time-domain (FDTD) method is used to analyze the optical behavior of the proposed SPR sensor. The thickness of the bimetallic layers and the number of layers of 2D materials are optimized to obtain maximum sensitivity for various sensing medium refractive indices ranging from 1.33 to 1.335 RIU. The maximum sensitivity of 348 deg/RIU is obtained with a thickness of 33 nm Ag, a thickness of 15 nm Au and with monolayer WS 2 , and four layers of Ti 3 C 2 T x MXene at 633 nm. This excellent performance of the proposed structure makes it suitable for detecting biomolecules and other analytes.
materials science, multidisciplinary,nanoscience & nanotechnology,chemistry, physical