Intermittent Urinary Catheterization: The Impact of Training on a Low-Fidelity Simulator on the Self-Confidence of Patients and Caregivers

Dayane R. A. Silva,Alessandra Mazzo,Beatriz M. Jorge,Valtuir D. Souza Júnior,Laís Fumincelli,Rodrigo G. S. Almeida
DOI: https://doi.org/10.1002/rnj.226
2017-03-01
Rehabilitation Nursing
Abstract:PURPOSE: The purpose of this study was to identify how training on a low-fidelity simulator impacts the confidence of caregivers and patients with neurogenic bladder who use clean intermittent urinary catheterization.DESIGN: Quasi-experimental study.METHODS: Developed in a rehabilitation center in Brazil including patients who use clean intermittent urinary catheterization and caregivers from September to November 2013. After Ethics approval (Opinion 146/2012) during the nursing consultation, data were collected before and after training on a low-fidelity simulator.FINDINGS: A total of 36 respondents (72.0%) patients and 14 (28.0%) caregivers participated. The self-confidence acquired after training on low-fidelity simulators was significant.CONCLUSIONS: In this study sample, low-fidelity simulation was demonstrated to be an effective strategy for the development of self-confidence.CLINICAL RELEVANCE: Low-fidelity simulation training enables patients and caregivers to increase their self-confidence when performing clean intermittent urinary catheterization and should be used as a training strategy by healthcare professionals.
nursing,rehabilitation
What problem does this paper attempt to address?