A novel approach of optical biopsy using probe-based confocal laser endomicroscopy for peritoneal metastasis

Hisashi Hara,Tsuyoshi Takahashi,Rie Nakatsuka,Shigeyoshi Higashi,Tetsuji Naka,Kazuki Sumiyama,Yasuhiro Miyazaki,Tomoki Makino,Yukinori Kurokawa,Makoto Yamasaki,Shuji Takiguchi,Masaki Mori,Yuichiro Doki,Kiyokazu Nakajima
DOI: https://doi.org/10.1007/s00464-015-4626-7
2015-11-05
Surgical Endoscopy
Abstract:BackgroundIn digestive cancers, it is mandatory to diagnose peritoneal metastasis prior to selecting therapy. Therefore, exploratory laparoscopy has gained wider clinical acceptance. In laparoscopy, the peritoneal metastasis is pathologically confirmed by excisional biopsy; however, there remain technical difficulties in performing precise diagnosis and adequate biopsy on small peritoneal lesions without damaging organs. We have focused on “optical biopsy” using probe-based confocal laser endomicroscopy (pCLE). The aims of this study were (1) to optimize current CLE system for real-time observation of peritoneal metastases and (2) to assess its potential usefulness as diagnostic modality in preclinical settings.MethodsTo optimize condition and evaluate feasibility, we prepared peritoneal metastasis mice model with gastric cancer cell line (MKN-45). On Day 10 after seeding, the mice were laparotomized and performed pCLE observations with CellvizioLAB (LSU-F 400/488 nm, Mauna Kea Technologies, Paris, France). We evaluated two different CLE probes, three different dyes, and optimal interval time. The detected sites were excised and pathologically evaluated on its morphology. Next, the feasibility and safety were validated in porcine model for clinical usage. After injection of fluorescein, pCLE was applied for the observation of intra-abdominal organs.ResultA miniature probe-type pCLE system with 60 μm focal depth (UltraMini O) and 1 % fluorescein dye was chosen for good visualization in mice model. The irregular microarchitecture images suspected to malignancy were obtained from the metastases. In the porcine model, observation of abdominal organs was feasible without any organ injury in the laparoscopic procedures. The dosage of 1 % fluorescein (3 ml/body) was appropriate in observing intra-abdominal organs, and each intra-abdominal organ was clearly observed with the same imaging quality we obtained in mice model.ConclusionThe pCLE was feasible and safe and potentially useful for the diagnosis of the peritoneal metastasis in in vivo animal models.
What problem does this paper attempt to address?