GIOVE: a new detector setup for high sensitivity germanium spectroscopy at shallow depth

G. Heusser,M. Weber,J. Hakenmüller,M. Laubenstein,M. Lindner,W. Maneschg,H. Simgen,D. Stolzenburg,H. Strecker
DOI: https://doi.org/10.1140/epjc/s10052-015-3704-2
IF: 4.991
2015-11-01
The European Physical Journal C
Abstract:We report on the development and construction of the high-purity germanium spectrometer setup GIOVE (Germanium Inner Outer VEto), recently built and now operated at the shallow underground laboratory of the Max-Planck-Institut für Kernphysik, Heidelberg. Particular attention was paid to the design of a novel passive and active shield, aiming at efficient rejection of environmental and muon induced radiation backgrounds. The achieved sensitivity level of ≤$$\le $$100 μ$$\upmu $$Bq kg-1$$^{-1}$$ for primordial radionuclides from U and Th in typical γ$$\gamma $$ ray sample screening measurements is unique among instruments located at comparably shallow depths and can compete with instruments at far deeper underground sites.
physics, particles & fields
What problem does this paper attempt to address?