P268 Artificial Intelligence and Panendoscopy – Automatic Detection of Pleomorphic Lesions in Multibrand Device-Assisted Enteroscopy
M P Araújo Martins,M Mascarenhas,J Afonso,T Ribeiro,P Cardoso,F Mendes,H Cardoso,P Andrande,M Mascarenhas Saraiva,J Ferreira,S Lopes,G Macedo
DOI: https://doi.org/10.1093/ecco-jcc/jjad212.0398
2024-01-01
Journal of Crohn's and Colitis
Abstract:Abstract Background Device-assisted enteroscopy (DAE) stands as the sole diagnostic and therapeutic procedure capable of thoroughly examining the entire gastrointestinal (GI) tract. Nevertheless, its diagnostic yield falls short in ensuring a cost-effective panendoscopy and there is still a significant interobserver variability during the procedure. Multi-layered convolutional neural networks (CNN) have proven beneficial in numerous medical applications, yet there is a noticeable gap in research regarding their implementation in DAE. The aim of this study is to develop and a validate a multidevice CNN for panendoscopic detection of pleomorphic lesions (vascular lesions, hematic residues, protruding lesions, ulcers and erosions) during DAE. Methods In a retrospective analysis of 338 DAE procedures conducted at two specialized centers, frames from 152 single-balloon enteroscopies (Fujifilm®), 172 double-balloon enteroscopies (Olympus®), and 14 motorized spiral enteroscopies (Olympus®) were used to construct and validate the CNN. The dataset, comprising 40,655 images, was divided into a training dataset (90% of images, n=36,599) and a validation dataset (10% of images, n=4,066). We conducted a 5-fold cross validation, during training dataset. Primary outcomes were sensitivity, specificity, accuracy, and area under the precision recall curve (AUC-PR). Results During the training dataset's 5-fold cross-validation, the model demonstrated a mean sensitivity of 88.7% (88.0 – 89.5%), specificity of 98.0% (97.8 – 98.1%), PPV of 92.6% (92.0 – 93.1%), PPN of 97.0% (96.8 – 97.2%), with a mean accuracy of 96.0% (95.8 – 96.2%). During validation dataset, the CNN presented 88.9% sensitivity, 98.9% specificity, 95.8% PPV, 97.1% NPV, 96.8% accuracy and AUC-PR of 0.97. The CNN processed 124 frames per second. Conclusion This is the first CNN that can detect pleomorphic lesions in a panendoscopic and multidevice scenario (containing the majority of DAE devices used in medical practice). The model accurately identified pleomorphic lesions throughout the GI tract, featuring a short processing frame rate that may allow its application in real-time clinical procedures. The development and application of these systems could amplify the indications and benefits of DAE, increasing its diagnostic yield and cost-effectiveness.
gastroenterology & hepatology