Rotational Stiffness of Three-Story Tunnel Form Structure under Uniformly Static Loading

Mohd Samsudin Abdul Hamid,Syahmi Aidi Shahbudin
DOI: https://doi.org/10.1007/s11668-021-01275-8
2021-11-08
Journal of Failure Analysis and Prevention
Abstract:Initially, tunnel form structure was constructed as innovative approach in construction of building and known as approached in Industrialized Building System. Tunnel form structure constructed with reinforced concrete slab and shear wall that is functional to transmit load from top floor to foundation. Three-story tunnel form structure was constructed with one-third scale. An experiment under uniformly static loading for double-layer reinforcement in the tunnel form structure examined the rotational stiffness. The load was applied at the top floor and uniformly distributed to provide homogeneous load distribute to the tunnel form structure. Maximum rotation angle of the system is 4.327 × 10−4 rad with 694.43 Nm/rad. It was reported the maximum load is 6.11 kN with maximum deformation of 17.68 mm. Furthermore, minor crack majorly occurs at the top floor because of the maximum stress due to applied load but robust performance at the lower floor without failure. It is important to ensure the structure able to absorb energy from the applied load to avoid failure. The increasing of load is increasing the deformation with minimal rotation provide stiffness of the structural system under any type of loading applied. Therefore, this article finding was found suitable to provide suitable reinforced concrete design to minimize failure mechanism due to maximum load and angle rotation especially for multi-story structure.
What problem does this paper attempt to address?