Influence of water feeding pattern on the nitrification efficiency of the deep sequencing constructed wetlands
liu zhen,liu tao,zhou jian,li chuansong
DOI: https://doi.org/10.13637/j.issn.1009-6094.2017.04.044
2017-01-01
Abstract:This paper takes it as its objective to deal with the problems of vast-spaced and low efficient constructed wetlands inwinter. For the research purpose,we have investigated the efficiency of the reactor during the set-up period and settled down NH;-N removal efficiency successfully for 6-14 days later,when the reactor tends to increase gradually and finally reach 76. 16%till the 14 th day. In so doing,we have made careful investigations over the impacts of the water feeding pattern and the operational conditions on the nitrification efficiency of the deep sequencing constructed wetlands( DSCW) in hoping to develop a kind of highly efficient nitrification technology for treating the tailing water in the sewage-processing plant. The results of our investigation and testing have shown that,the nitrification efficiency can be affected significantly by the water feeding pattern,the feeding duration,as well as the idling time. For example,when the operation is done in a"continuous influent"pattern,or in a"5. 5 h continuous influent-0. 5 h intermittent effluent",or in the manner of"0. 25 h continuous influent-1. 25 h intermittent effluent-4. 5 h idling",the mass concentrations of effluent NH;-N should be8. 70 mg/L,2. 87 mg/L and 5. 31 mg/L,with the average removal efficient rates being 42. 34%,82. 03% and 64. 67%,respectively. As compared with "the continuous influent and effluent"pattern,when operational pattern is chosen to be the "continuous influent-intermittent effluent,"the removal efficiency of NH;-N can be expected to increase by 22. 33%-39. 69%. Moreover,when the sewage feeding durations were taken as 5. 5 h,7. 5 h and 11. 5 h,the mass concentrations of effluent NH;-N should be 2. 89 mg/L,1. 59 mg/L and 1. 40 mg/L,respectively,with the average removal efficiency of NH;-N being 81. 82%,88. 12% and 89. 91%,accordingly. On the other hand,if idling time were to last 0,2 h and 4 h,the mass concentrations of effluent NH;-N would turn to be 1. 59 mg/L,0. 91 mg/L and 0. 97mg/L,with the average removal efficiency of NH;-N being88. 12%,94. 46% and 92. 60%,relatively. Thus,as compared with no idle time,the average removal efficiency of NH;-N may rise by 6. 34% and 4. 48% for 2 h and 4 h of the idling time.But,when the reactor is operated or working under the condition of( 20 ± 3) ℃ with NH;-N load 35. 56 g/( m2·d)( 7. 5 h continuous influent-0. 5 h intermittent effluent-2 h idle),the average mass concentration of effluent NH;-N can be expected to reach0. 91 mg/L,with its removal efficiency of 94. 46%,which suggests that NH;-N removal efficiency has gained a substantial increase.