A new detection scheme for ultrafast 2 D COSY
S. Cai,M. Zhao,Z. Chen
2009-01-01
Abstract:Introduction NMR plays a significant role in determining structures and dynamics of various physical, chemical, and biological systems at molecular level. The introduction of 2D techniques accelerates and extends the application of NMR spectroscopy. Unfortunately, numerous t1 increments have to be collected for a 2D spectrum with good resolution, which leads the experiment fairly time-consuming. The spatial encoding ultrafast technique enables 2D NMR spectra to be acquired in a single scan [1]. In this abstract, a new ultrafast 2D COSY method based on continuous constant-time phase-modulated spatial encoding was proposed and experiments were performed to verify its feasibility and advantages over the previous method. Methods The pulse sequence is shown in Fig. 1a. A π-π chirped pulse scheme is used to encode evolution phases along the z-orientation. For the π chirped pulses, the RF sweeps from initial frequency offset Oi to final frequency offset Of at a constant rate. A pair of bipolar z-orientation field gradients (+Ge, –Ge) over equal time during the course of encoding are used. Two π/2 hard pulses are respectively imposed before and after the π-π module. A z-orientation field gradient (Gp) is also necessary to localize the peaks in the direct dimension. The EPI detection block is used in the decoding period. In the EPI detection block, the evolution phases at different coordinates are decoded with the help of a pair of bipolar z-orientation field gradients (Ga and –Ga). The EPI detection block is repeated N2 times. Experiments were performed at 298 K on a Varian NMR System 500 MHz spectrometer using a 5 mm H{N-P} indirect detection probe equipped with 3D gradient coils. A sample of n-butylbromide/CDCl3 was used. The duration of the π/2 RF pulses was 10.8 μs. The effective sample length was L = 1.6 cm. The π chirped pulses were created from the Pbox subroutine libraries at a digitization rate of 1.0 μs with an adiabatic coefficient of 1.2 to fulfill the adiabatic passage requirements. The gradient switching time was δ = 5.0 μs, and Ga = 30 G/cm, Ta = 200 μs, and N2 = 80. The other relevant parameters were as follows: Ge = 15 G/cm, max 1 t = 40 ms, tmix = 10 ms, Gp = 10 G/cm, and tp = 0.25 ms. For comparison, real-time phase-modulated encoding experiment was also carried out (Fig. 1b) [2]. The effective encoding time was 78.95 ms. The π/2 pulse was created at a digitization rate of 1.0 μs with a adiabatic coefficient of 0.068. The other relevant parameters were as follows: ( / 2) e G π = 3.91 G/cm, ( ) e G π = 37.2 G/cm, tmix = 20 ms, Gp = 10 G/cm, and tp = 0.05 ms. Results and Discussion The resulting 2D H-H COSY spectra of the n-butylbromide/CDCl3 sample are illustrated in Fig. 2, together with the initial parts of the time-domain signals. Both spectra were processed with the same procedure and same post-processing parameters. The comparison between the two spectra (Fig. 2a and 2b) indicates that they have approximately identical resolution in the direct dimension, while the spectrum obtained with our new method has higher resolution in the indirect dimension. The higher resolution would benefit the application of ultrafast 2D COSY method on complex proton systems. The comparison between the time-domain signals in Fig. 2c and 2d indicates that the signal obtained with our new method has higher signal-to-noise ratio (SNR) than that obtained with the real-time phase-modulated encoding method. Four echoes can be clearly observed during each +Ga or –Ga sampling period in Fig. 2c, whereas the echoes in Fig. 2d are not so clear due to serious noises. The better result from our new method (higher resolution and SNR) may be mainly attributed to the less diffusion and transverse relaxation effects, the larger spatio-temporal encoding constant and the elimination of J splitting [3]. In practice, it is significant for an experiment to be performed rapidly and conveniently. In constant-time phase-modulated encoding 2D COSY experiment, instead of two different chirped pulses, two same π chirped pulses, together with a pair of reverse gradients (+Ge, –Ge) over equal time during the course of spin encoding are used. So the experiment is relatively easy to implement, without too much cumbersome parameter calibration work. By contrast, in the real-time phase-modulated encoding 2D COSY experiment, the conditions of ( / 2) ( ) 1,max 1,max ( / 2) ( ) 2 e e t t G G π π π π = and ( ) ( / 2) e e G G π π ≈ are chosen for the indirect-domain encoding, and the π/2 and π chirped pulses should be set according to the relevant parameters ( ( / 2) e G π , ( ) e G π , ( / 2) 1,max t π , and ( ) 1,max t π ). Therefore, a longer time is needed to calibrate these parameters and generate the π/2 and π chirped pulses for a 2D COSY spectrum. Moreover, the result of real-time phase-modulated encoding experiment is more sensitive to experimental parameter variations, such as pulse power or frequency offset [3]. In summary, compared to the previous real-time phase-modulated method, the present ultrafast COSY method not only gives much better spectral SNR and resolution, but also is much easier to implement. Acknowledgment This work was supported by the NNSF of China under Grants 10875101 and the Key Project of Chinese Ministry of Education under Grant 109092. References [1] Frydman L, et al. Proc. Natl. Acad. Sci. U. S. A. 99 (2002) 15858-15862. [2] Tal A, et al. J. Magn. Reson. 176 (2005) 107-14. [3] Giraudeau P, et al. J. Magn. Reson. 195 (2008) 9-16. Fig. 2 2D H-H COSY spectra of n-butylbromide/CDCl3 sample. (a) Spectrum obtained using the pulse sequence shown in Fig. 1a; (b) spectrum obtained using the pulse sequence shown in Fig. 1b; (c) time-domain signal corresponding to (a) acquired in the first two decoding periods; (d) time-domain signal corresponding to (b) acquired in the first two decoding periods. Both (a) and (b) were recorded within about 20 s. Their accumulated projections along both direct and indirect dimensions are shown in an absolute value mode for comparison. Fig. 1 (a) Constant-time phase-modulated encoding sequence; (b) real-time phase-modulated encoding sequence.