A multifaceted quality improvement strategy reduces the risk of catheter-associated urinary tract infection

Cecelia N Theobald,Matthew J Resnick,Thomas Spain,Robert S Dittus,Christianne L Roumie,Cecelia N. Theobald,Matthew J. Resnick,Robert S. Dittus,Christianne L. Roumie
DOI: https://doi.org/10.1093/intqhc/mzx073
2017-06-17
International Journal for Quality in Health Care
Abstract:OBJECTIVE: Catheter-associated urinary tract infections (CAUTIs) are common and preventable hospital-acquired infections, yet their rate continues to rise nationwide. We describe the implementation of a multifaceted program to reduce catheter use and CAUTI rates while simultaneously addressing barriers to long-term success.DESIGN/SETTING/PARTICIPANTS: Pre-post study of medical inpatient veterans between December 2012 and February 2015.INTERVENTION: Five component intervention: (i) a bedside catheter reminder; (ii) multidisciplinary educational campaign; (iii) structured catheter order set with clinical decision support; (iv) automated catheter discontinuation orders; and (v) protocol for post-catheter removal care.MAIN OUTCOME MEASURE(S): Catheter utilization rates and CAUTI rates on the study ward were followed during the 14-week baseline period, the 27-week transition/intervention period and the 70-week period of full implementation/sustainability. Rates of patient falls per bed days and catheter reinsertions were collected during the same time periods as balancing measures.RESULTS: Catheter use declined by 35% from the baseline period to the full implementation/sustainability period. This improvement was not realized until deployment of the structured electronic orders with automated catheter discontinuation and protocolized post-catheter care. The average number of days between CAUTIs on the study ward increased from 101 days in the baseline period to over 400 days in the full implementation/sustainability period. There was no significant change in the rates of falls or catheter reinsertions during the study period.CONCLUSIONS: A multicomponent intervention aimed specifically at targeting local barriers was successful in reducing catheter utilization as well as CAUTIs in a veteran population without compensatory increase in patient falls or catheter replacement.
health care sciences & services,health policy & services
What problem does this paper attempt to address?