Anaerobic Corrosion of 304 Stainless Steel Caused by the Pseudomonas aeruginosa Biofilm

Ru Jia,Dongqing Yang,Dake Xu,Tingyue Gu
DOI: https://doi.org/10.3389/fmicb.2017.02335
IF: 5.2
2017-11-27
Frontiers in Microbiology
Abstract:<i>Pseudomonas aeruginosa</i> is a ubiquitous bacterium capable of forming problematic biofilms in many environments. They cause biocorrosion of medical implants and industrial equipment and infrastructure. Aerobic corrosion of <i>P. aeruginosa</i> against stainless steels has been reported by some researchers while there is a lack of reports on anaerobic <i>P. aeruginosa</i> corrosion in the literature. In this work, the corrosion by a wild-type <i>P. aeruginosa</i> (strain PAO1) biofilm against 304 stainless steel (304 SS) was investigated under strictly anaerobic condition for up to 14 days. The anaerobic corrosion of 304 SS by <i>P. aeruginosa</i> was reported for the first time. Results showed that the average sessile cell counts on 304 SS coupons after 7- and 14-day incubations were 4.8 × 10<sup>7</sup> and 6.2 × 10<sup>7</sup> cells/cm<sup>2</sup>, respectively. Scanning electron microscopy and confocal laser scanning microscopy corroborated the sessile cell counts. The X-ray diffraction analysis identified the corrosion product as iron nitride, confirming that the corrosion was caused by the nitrate reducing biofilm. The largest pit depths on 304 SS surfaces after the 7- and 14-day incubations with <i>P. aeruginosa</i> were 3.9 and 7.4 μm, respectively. Electrochemical tests corroborated the pitting data.
microbiology
What problem does this paper attempt to address?