Noise attenuation capacity of a Helmholtz resonator

Chenzhi CAI,Cheuk Ming MAK
DOI: https://doi.org/10.1016/j.advengsoft.2017.12.003
IF: 4.255
2018-02-01
Advances in Engineering Software
Abstract:Helmholtz resonator (HR) is one of the most basic acoustic models and has been widely used in engineering applications due to its simple, tunable and durable characteristics. The transmission loss index is mainly used to evaluate the acoustic transmission performance. Based on the transmission loss index, this paper proposes the noise attenuation capacity index as one of the key parameters to evaluate the noise attenuation performance of a HR. The noise attenuation capacity is defined as the integral of transmission loss in the frequency domain. The theoretical formula of a HR's noise attenuation capacity is first derived in this study. It indicates that the noise attenuation capacity of a HR is only related to geometries of the neck and duct's cross-sectional area. The cavity volume has no effects on its noise attenuation capacity. The proposed theoretical formula of a HR's noise attenuation capacity is validated by Finite Element Method (FEM) simulation using commercial software (COMSOL Multiphysics). The proposed noise attenuation capacity of a HR should therefore be considered as one of the main acoustic characteristics of a HR. It is hoped that the present study could provide a stepping stone for the investigation of the HR's or other silencers’ noise attenuation capacity and potential applications in all research areas in respect of the HR.
computer science, interdisciplinary applications,engineering, multidisciplinary, software engineering
What problem does this paper attempt to address?