Accurate quantitative CF-LIBS analysis of both major and minor elements in alloys via iterative correction of plasma temperature and spectral intensity

Shuxia ZHAO,Lei ZHANG,Jiajia HOU,Yang ZHAO,Wangbao YIN,Weiguang MA,Lei DONG,Liantuan XIAO,Suotang JIA
DOI: https://doi.org/10.1088/2058-6272/aa97ce
2018-01-23
Plasma Science and Technology
Abstract:The chemical composition of alloys directly determines their mechanical behaviors and application fields. Accurate and rapid analysis of both major and minor elements in alloys plays a key role in metallurgy quality control and material classification processes. A quantitative calibration-free laser-induced breakdown spectroscopy (CF-LIBS) analysis method, which carries out combined correction of plasma temperature and spectral intensity by using a second-order iterative algorithm and two boundary standard samples, is proposed to realize accurate composition measurements. Experimental results show that, compared to conventional CF-LIBS analysis, the relative errors for major elements Cu and Zn and minor element Pb in the copper-lead alloys has been reduced from 12%, 26% and 32% to 1.8%, 2.7% and 13.4%, respectively. The measurement accuracy for all elements has been improved substantially.
physics, fluids & plasmas
What problem does this paper attempt to address?