Experimental and numerical studies on air cooling and temperature uniformity in a battery pack

Seham Shahid,Martin Agelin‐Chaab,Martin Agelin-Chaab
DOI: https://doi.org/10.1002/er.4018
IF: 4.6
2018-02-09
International Journal of Energy Research
Abstract:In this paper, a passive technique is examined by adding an inlet plenum to reduce the maximum temperature and improve temperature uniformity in a simple battery pack. The inlet plenum changes the direction of the flow and dramatically reduces the issues of air recirculation and dead‐air regions between adjacent cells. The dimensions of the plenum and Reynolds number were optimized to enhance cooling and temperature uniformity at the cell and pack level. The results indicated that by increasing the Reynolds number to 7440, the maximum temperature decreased by 18.3% and the temperature uniformity increased 54.6%. However, there was no significant change in the maximum temperature and temperature uniformity beyond the Reynolds number of 7440. The developed battery pack achieved the desired temperature uniformity at the cell and pack level to less than 5°C. In this paper, a passive technique to improve temperature uniformity in a simple battery pack by adding an inlet plenum is examined. The focus is placed on enhancing temperature uniformity and reducing the maximum temperatures at the cell and pack level. This battery pack has a very simple configuration, requires no moving parts, and introduces mixing and turbulence in the air flow to provide a high level of temperature uniformity.
energy & fuels,nuclear science & technology
What problem does this paper attempt to address?