Impact of Drug Formulation Variables on Silicone Oil Structure and Functionality of Prefilled Syringe System

Galen H Shi,Ganapathy Gopalrathnam,Sharon L Shinkle,Xia Dong,Jeffrey D Hofer,Eric C Jensen,Natarajan Rajagopalan,Galen H. Shi,Sharon L. Shinkle,Jeffrey D. Hofer,Eric C. Jensen
DOI: https://doi.org/10.5731/pdajpst.2017.008169
2017-10-12
PDA Journal of Pharmaceutical Science and Technology
Abstract:Use of prefilled syringes to self-administer biologics via subcutaneous administration provides convenience to patients. The barrel interior of prefilled syringes is typically coated with silicone oil for lubrication to aid plunger movement at the time of administration. This study intended to evaluate the impact of formulation variables on the silicone oil on the barrel interior surface. Characterization techniques including syringe glide force, break loose force, Schlieren imaging, contact angle, inductively coupled plasma spectrometry, and thin film interference reflectometry were used in assessing the interactions. Data indicated that formulation variables such as pH, buffer/tonicity agent type and concentration, and surfactant present in the formulation can effect silicone oil lubrication of prefilled syringes, leading to changes in functional properties of the syringe over time. Syringe samples containing acetate and histidine buffers showed an increase in glide force at accelerated storage temperature conditions, but the change was minimal at 5 °C. The samples with the highest glide force correlated with the presence of mannitol in combination with sodium acetate buffer. Sodium chloride had lesser impact on glide force than mannitol. Samples with higher glide force exhibited a substantial change in the silicone oil layer of the syringe, as observed with Schlieren imaging, as well as a significant reduction in surface hydrophobicity, as demonstrated through contact angle measurement. These data indicated that the structure of the siliconized surface can change over time in contact with different formulations. During formulation development of drug products in prefilled syringes, in addition to potential impact on molecule stability, the selection of formulation variables should also be guided by assessing the impact to syringe functionality with the glide force as one of the key parameters.<i>LAY ABSTRACT:</i> Self-administering drug products packaged in prefilled syringes provides convenience to patients. The interior of a prefilled glass syringe is typically lubricated with silicone oil for easy plunger movement during injection. This article discusses the impact of formulation excipients on silicone oil coating inside the syringe. Characterization techniques were used to assess the ease of plunger movement and structure of the silicone coating. Data indicate formulation excipients can affect silicone oil distribution of prefilled syringes, leading to an increase in plunger glide force at accelerated storage temperature conditions. The increase in glide force within a prefilled syringe with or without an auto-injector can have an impact on dose accuracy and user experience. Syringes with a higher plunger glide force appeared to exhibit a change over time in surface energy and structure of the silicone oil layer in contact with particular formulations.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the influence of drug formulation variables on the structure and function of silicone oil in pre - filled syringe systems. Specifically, the study focuses on how factors such as pH value, buffer / tonicity regulator type and concentration, and surfactants in the formulation affect the lubricating properties of silicone oil, and further affect the functional characteristics of the syringe, such as sliding resistance and initial push resistance. The study evaluates the influence of these factors through a variety of characterization techniques (such as syringe sliding resistance test, breakthrough force test, Schlieren imaging, contact angle measurement, inductively coupled plasma spectroscopy analysis, and thin - film interference reflection measurement). The study shows that different formulation components can change the distribution and structure of the silicone oil coating, leading to changes in the syringe's sliding resistance, which may affect the accuracy of drug dosing and the patient's experience of use. Therefore, when developing drug formulations in pre - filled syringes, in addition to considering molecular stability, the influence of formulation variables on syringe function should also be evaluated, especially the key parameter of sliding resistance.