Influence of Line Pair Selection on Flame Tomography Using Infrared Absorption Spectroscopy

Kin-Pang Cheong,Liuhao Ma,Zhen Wang,Wei Ren
DOI: https://doi.org/10.1177/0003702818815181
2018-12-10
Applied Spectroscopy
Abstract:We report the influence of absorption line selection on the tomographic results for high-temperature flames by numerical and experimental methods. Different combinations of infrared H 2 O absorption transitions are utilized with the Tikhonov-regularized Abel inversion to reconstruct the radial distribution of temperature and H 2 O concentration in a flat flame. It is shown that besides using the mathematical algorithm such as regularization, selecting a line pair with a large Δ E′′ (>1390 cm −1 ) also reduces the reconstruction uncertainty at 300–2000 K. In this study, a proper selection of absorption line pairs reduces the reconstruction uncertainty by 25% at the same level of noise. The line pair of H 2 O transitions at 4029.524 cm −1 and 4030.729 cm −1 is recommended for the tomography of high-temperature flames at 1000–3000 K, whereas the line pair of 7185.597 cm −1 and 7444.352 cm −1 can be used at 300–1000 K.