Nitrogen doped carbon nanofibers loaded with hierarchical vanadium tetrasulfide for the voltammetric detection of the non-steroidal anti-prostate cancer drug nilutamide

Kumuthini Rajendran,Thangavelu Kokulnathan,Shen-Ming Chen,Joseph Anthuvan Allen,Chinnuswamy Viswanathan,Helen Annal Therese
DOI: https://doi.org/10.1007/s00604-019-3251-x
IF: 5.7
2019-02-01
Microchimica Acta
Abstract:An electrochemical sensor is described for the determination of nilutamide (NLM) in biological fluids. A flexible mat of nitrogen-doped carbon nanofibers (NCNFs) was prepared by electrospinning. This was followed by carbonization and the growth of one-dimensional vanadium tetrasulfide (VS4) nanorods in the circumference of the NCNFs by a solvothermal route. The material was used to modify a glassy carbon electrode (GCE). Cyclic voltammetry and amperometry revealed an excellent electrocatalytic activity of the VS4/NCNF mat towards NLM at a working potential of – 0.57 V (vs Ag/AgCl). The modified GCE has a wide linear range (0.001–760 μM), a low limit of detection (90 pM), good stability, and fast response. It was used to detect NLM in spiked serum and urine samples.Graphical abstractSchematic presentation of a glassy carbon electrode (GCE) composed of free-standing nitrogen-doped carbon nanofibers decorated with vanadium tetrasulfide (Patronite) nanorods (VS4/NCNF). It was fabricated by electrospinning followed by stabilization and carbonization. The GCE responds to nilutamide (NLM) with excellent selectivity and nanomolar sensitivity
chemistry, analytical
What problem does this paper attempt to address?