Electrochemical Sensor Based on Molecularly Imprinted Polymer for the Detection of Cefalexin

Bogdan Feier,Adrian Blidar,Alexandra Pusta,Paula Carciuc,Cecilia Cristea
DOI: https://doi.org/10.3390/bios9010031
2019-02-27
Biosensors
Abstract:In this study, a new electrochemical sensor was developed for the detection of cefalexin (CFX), based on the use of a molecularly imprinted polymer (MIP) obtained by electro‒polymerization in an aqueous medium of indole-3-acetic acid (I3AA) on a glassy carbon electrode (GCE) and on boron-doped diamond electrode (BDDE). The two different electrodes were used in order to assess how their structural differences and the difference in the potential applied during electrogeneration of the MIP translate to the performances of the MIP sensor. The quantification of CFX was performed by using the electrochemical signal of a redox probe before and after the rebinding of the template. The modified electrode was characterized using atomic force microscopy (AFM), scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The influence of different parameters on the fabrication of the sensor was tested, and the optimized method presented high selectivity and sensitivity. The MIP-based electrode presented a linear response for CFX concentration range of 10 to 1000 nM, and a limit of detection of 3.2 nM and 4.9 nM was obtained for the BDDE and the GCE, respectively. The activity of the sensor was successfully tested in the presence of some other cephalosporins and of other pharmaceutical compounds. The developed method was successfully applied to the detection of cefalexin from real environmental and pharmaceutical samples.
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to develop an electrochemical sensor capable of sensitive and selective detection of cefalexin (CFX). Specifically, the researchers aim to achieve high - sensitivity and high - selectivity detection of CFX through molecularly imprinted polymer (MIP) technology combined with electrochemical methods. ### Problem Background The overuse and abuse of antibiotics have led to the development of antibiotic resistance, which has become one of the most serious public health problems today. Cefalexin is a commonly used β - lactam antibiotic, belonging to the first - generation cephalosporins, and is widely used in the treatment of diseases such as respiratory tract infections, pneumonia, and urinary tract infections. However, its residues in the environment may cause health problems, such as allergic reactions and broad - spectrum antibiotic resistance. Therefore, there is an urgent need to develop rapid and selective antibiotic detection methods. ### Research Objectives The objective of this paper is to develop an electrochemical sensor based on molecularly imprinted polymers for the detection of cefalexin. Specific objectives include: 1. **Improve selectivity and sensitivity**: Ensure the selectivity and sensitivity of the sensor to cefalexin by using molecularly imprinted polymers (MIP). 2. **Optimize sensor performance**: Evaluate the influence of different electrode materials (such as glassy carbon electrode GCE and boron - doped diamond electrode BDDE) and electropolymerization conditions on sensor performance. 3. **Verify practical applications**: Apply the developed sensor to actual environmental and drug samples to verify its effectiveness and reliability. ### Solutions The researchers selected indole - 3 - acetic acid (I3AA) as a monomer and prepared MIP on GCE and BDDE by electropolymerization. The formation process of MIP includes the following steps: 1. **Electrode pretreatment**: Polish the electrode with a 0.05 µm alumina suspension and rinse it with ultrapure water. 2. **MIP electropolymerization**: Immerse the electrode in a phosphate buffer solution containing I3AA and CFX and perform cyclic voltammetry (CV) electropolymerization. 3. **Template removal**: Remove the template molecule CFX by soaking in methanol, 0.1 M NaOH or PBS. 4. **Sensor characterization**: Characterize the modified electrode using atomic force microscopy (AFM), scanning electron microscopy (SEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). 5. **Detection performance evaluation**: Evaluate the sensor's response to CFX by measuring the current change in potassium ferricyanide solution through differential pulse voltammetry (DPV). Finally, the sensor exhibited a linear response in the CFX concentration range of 10 to 1000 nM, and the detection limits of BDDE and GCE were 3.2 nM and 4.9 nM, respectively. In addition, the sensor still showed good selectivity and low interference in the presence of other antibiotics and drug compounds. In conclusion, this study successfully developed an MIP - based electrochemical sensor that can sensitively and selectively detect cefalexin, providing a new tool for antibiotic pollution monitoring.