Long term stress monitoring on pc beam by using elasto-magnetic sensor
Shoji KUROKAWA,Sunaryo,Keiji SHIMANO,Ming L. WANG
2002-01-01
Abstract:Steel together with concrete is the main structural material of the infrastructures. Along with social development, steel materials have been used for a variety of structures, such as, highway bridges, railroad bridges and buildings. In recent years, many structures have been deteriorating. In order to carry out maintenance management of the structures economically and rationally, it is necessary to evaluate their life cycle cost (LCC) based on the following stages, i.e., construction, inspection, repair, maintenance management, destruction and/or dismantlement [1]. Research on the optimization of maintenance plan has been reported by taking into account inspection expense and inspection accuracy on a description model of the LCC of civil engineering structure [2]. In considering a maintenance plan for Pre-stressed Concrete (PC) structure which aims to reduce its LCC, it is requested that the measurement system should fulfill “AtoE” characteristics, i.e., (A)ccuracy, (B)enefit , (C)ompact, (D)urable and (E)asy to operate, besides enable to measure the actual stress of the PC tendon, non-destructive to the PC tendon itself and no damage to its protection sheath [3]. However, the stress measurement method that fully satisfies such characteristics was not found. Elasto-Magnetic (EM) actual stress measurement method by utilizing the sensitivity of incremental magnetic permeability due to stress change has been being developed [4,5,6]. Numerous tests of various steel materials by applying this measurement method in which satisfy above-mentioned characteristics have been conducted [7]. It has been proved that EM measurement method enable to measure actual stress of steel wire, PC bar and PC strand precisely without destroying their polyethylene covering sheath [8]. For a PC structure member, although pre-stressing measurement by the load-cell installed at a jack end can be performed before fixation, but the problem becomes difficult after fixation of the PC tendon. Therefore, in order to solve the problem, the steel tendon stress measurement test on outer cable PC beam was conducted by utilizing EM sensor. By comparing with load-cell and strain gage measurement results, the actual stresses of the outer PC tendon in the following conditions are clearly investigated: actual mechanical properties of PC wire under tension test, pre-stress change due to set-loss at PC tendon fixation stage, pre-stress change due to PC tendon relaxation, concrete creep and shrinkage at long-term pre-stressing stage, PC tendon pre-stress change of PC beam under cyclic fatigue loading and actual pre-stress change due to re-pre-stress process. As the result of the test, it is confirmed that EM stress measurement technology can provide adequate accuracy and reliability to monitor actual stresses of PC tendons during a life cycle of PC structures.