Rapid ultrasensitive detection platform for antimicrobial susceptibility testing

Mehmet F. Cansizoglu,Yusuf Talha Tamer,Michael Farid,Andrew Y. Koh,Erdal Toprak
DOI: https://doi.org/10.1371/journal.pbio.3000291
IF: 9.8
2019-05-30
PLoS Biology
Abstract:Rapid detection and phenotyping of pathogenic microbes is critical for administration of effective antibiotic therapies and for impeding the spread of antibiotic resistance. Here, we present a novel platform, rapid ultrasensitive detector (RUSD), that utilizes the high reflectance coefficient at high incidence angles when light travels from low- to high-refractive-index media. RUSD leverages a principle that does not require complex manufacturing, labeling, or processing steps. Utilizing RUSD, we can detect extremely low cell densities (optical density [OD] ≥ 5 × 10<sup>−7</sup>) that correspond to approximately 20 bacterial cells or a single fungal cell in the detection volume, which is nearly 4 orders of magnitude more sensitive than standard OD methods. RUSD can measure minimum inhibitory concentrations (MICs) of commonly used antibiotics against gram-negative and gram-positive bacteria, including <em>Staphylococcus aureus</em>, <em>Pseudomonas aeruginosa</em>, and <em>Escherichia coli</em>, within 2 to 4 h. Here, we demonstrate that antibiotic susceptibility tests for several pathogens can rapidly be performed with RUSD using both small inoculum sizes (500 cells/mL) and larger inoculum sizes (5 × 10<sup>5</sup> cells/mL) used in standard antibiotic susceptibility tests. We anticipate that the RUSD system will be particularly useful for the cases in which antibiotic susceptibility tests have to be done with a limited number of bacterial cells that are available. Its compatibility with standard antibiotic susceptibility tests, simplicity, and low cost can make RUSD a viable and rapidly deployed diagnostic tool.
biochemistry & molecular biology,biology
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to detect the sensitivity of pathogenic microorganisms to antibiotics quickly and accurately. Specifically, traditional antibiotic sensitivity test methods (such as culture medium method, liquid minimum inhibitory concentration determination method and linear gradient diffusion method) usually take several hours to several days to complete, which is a huge challenge for clinical applications, especially in cases where it is necessary to quickly determine the optimal treatment plan to prevent the spread of antibiotic resistance. Therefore, there is an urgent need for a fast, economical and highly sensitive detection platform that can significantly reduce the time required to determine antibiotic sensitivity and allow earlier selection of optimized targeted therapies. To this end, the authors have developed a new platform named "Rapid Ultrasensitive Detector" (RUSD). RUSD utilizes the principle of high reflectivity of high - refractive - index media at high incident angles and does not require complex manufacturing, labeling or processing steps. Through RUSD, extremely low cell densities (optical density [OD] ≈ \(5\times10^{-7}\), equivalent to approximately 20 bacterial cells or one fungal cell) can be detected, which is nearly four orders of magnitude more sensitive than the standard OD method. In addition, RUSD can measure the minimum inhibitory concentration (MIC) of commonly used antibiotics against Gram - negative and positive bacteria (such as Staphylococcus aureus, Pseudomonas aeruginosa and Escherichia coli) within 2 to 4 hours. The RUSD system is particularly suitable for situations where the number of available bacterial cells is limited. Its compatibility with standard antibiotic sensitivity tests, simplicity and low cost make it a viable and rapidly deployable diagnostic tool.