A study of the radiation tolerance of poly-crystalline and single-crystalline CVD diamond to 800 MeV and 24 GeV protons

L Bäni,A Alexopoulos,M Artuso,F Bachmair,M Bartosik,H Beck,V Bellini,V Belyaev,B Bentele,A Bes,J-M Brom,M Bruzzi,G Chiodini,D Chren,V Cindro,G Claus,J Collot,J Cumalat,A Dabrowski,R D’Alessandro,D Dauvergne,W de Boer,S Dick,C Dorfer,M Dünser,V Eremin,G Forcolin,J Forneris,L Gallin-Martel,M-L Gallin-Martel,K K Gan,M Gastal,C Giroletti,M Goffe,J Goldstein,A Golubev,A Gorišek,E Grigoriev,J Grosse-Knetter,A Grummer,B Gui,M Guthoff,B Hiti,D Hits,M Hoeferkamp,T Hofmann,J Hosselet,J-Y Hostachy,F Hügging,C Hutton,J Janssen,H Kagan,K Kanxheri,G Kasieczka,R Kass,M Kis,G Kramberger,S Kuleshov,A Lacoste,S Lagomarsino,A Lo Giudice,I Lopez Paz,E Lukosi,C Maazouzi,I Mandic,C Mathieu,M Menichelli,M Mikuž,A Morozzi,J Moss,R Mountain,A Oh,P Olivero,D Passeri,H Pernegger,R Perrino,M Piccini,F Picollo,M Pomorski,R Potenza,A Quadt,F Rarbi,A Re,M Reichmann,S Roe,D A Sanz Becerra,M Scaringella,D Schaffner,C J Schmidt,S Schnetzer,E Schioppa,S Sciortino,A Scorzoni,S Seidel,L Servoli,D S Smith,B Sopko,V Sopko,S Spagnolo,S Spanier,K Stenson,R Stone,C Sutera,M Traeger,W Trischuk,M Truccato,C Tuve,J Velthuis,N Venturi,S Wagner,R Wallny,J C Wang,J Weingarten,C Weiss,T Wengler,N Wermes,M Yamouni,M Zavrtanik
DOI: https://doi.org/10.1088/1361-6463/ab37c6
2019-08-30
Abstract:Abstract We have measured the radiation tolerance of poly-crystalline and single-crystalline diamonds grown by the chemical vapor deposition (CVD) process by measuring the charge collected before and after irradiation in a 50 m pitch strip detector fabricated on each diamond sample. We irradiated one group of sensors with 800 MeV protons, and a second group of sensors with 24 GeV protons, in steps, to protons cm −2 and protons cm −2 respectively. We observe the sum of mean drift paths for electrons and holes for both poly-crystalline CVD diamond and single-crystalline CVD diamond decreases with irradiation fluence from its initial value according to a simple damage curve characterized by a damage constant for each irradiation energy and the irradiation fluence. We find for each irradiation energy the damage constant, for poly-crystalline CVD diamond to be the same within statistical errors as the damage constant for single-crystalline CVD diamond. We find the damage constant for diamond irradiated with 24 GeV protons to be and the damage constant for diamond irradiated with 800 MeV protons to be . Moreover, we observe the pulse height decreases with fluence for poly-crystalline CVD material and within statistical errors does not change with fluence for single-crystalline CVD material for both 24 GeV proton irradiation and 800 MeV proton irradiation. Finally, we have measured the uniformity of each sample as a function of fluence and observed that for poly-crystalline CVD diamond the samples become more uniform with fluence while for single-crystalline CVD diamond the uniformity does not change with fluence.
What problem does this paper attempt to address?