Peripheral nerve stimulation limits of a high amplitude and slew rate magnetic field gradient coil for neuroimaging

Ek T. Tan,Yihe Hua,Eric W. Fiveland,Mark E. Vermilyea,Joseph E. Piel,Keith J. Park,Vincent B. Ho,Thomas K. F. Foo
DOI: https://doi.org/10.1002/mrm.27909
2019-08-06
Magnetic Resonance in Medicine
Abstract:<h3 class="article-section__sub-title section1"> Purpose</h3><p>To establish peripheral nerve stimulation (PNS) thresholds for an ultra‐high performance magnetic field gradient subsystem (simultaneous 200‐mT/m gradient amplitude and 500‐T/m/s gradient slew rate; 1 MVA per axis [MAGNUS]) designed for neuroimaging with asymmetric transverse gradients and 42‐cm inner diameter, and to determine PNS threshold dependencies on gender, age, patient positioning within the gradient subsystem, and anatomical landmarks.</p><h3 class="article-section__sub-title section1"> Methods</h3><p>The MAGNUS head gradient was installed in a whole‐body 3T scanner with a custom 16‐rung bird‐cage transmit/receive RF coil compatible with phased‐array receiver brain coils. Twenty adult subjects (10 male, mean ± SD age = 40.4 ± 11.1 years) underwent the imaging and PNS study. The tests were repeated by displacing subject positions by 2‐4 cm in the superior–inferior and anterior–posterior directions.</p><h3 class="article-section__sub-title section1"> Results</h3><p>The x‐axis (left–right) yielded mostly facial stimulation, with mean Δ<i>G</i><sub>min</sub> = 111 ± 6 mT/m, chronaxie = 766 ± 76 µsec. The <i>z</i>‐axis (superior–inferior) yielded mostly chest/shoulder stimulation (123 ± 7 mT/m, 620 ± 62 µsec). Y‐axis (anterior–posterior) stimulation was negligible. X‐axis and <i>z</i>‐axis thresholds tended to increase with age, and there was negligible dependency with gender. Translation in the inferior and posterior directions tended to increase the x‐axis and <i>z</i>‐axis thresholds, respectively. Electric field simulations showed good agreement with the PNS results. Imaging at MAGNUS gradient performance with increased PNS threshold provided a 35% reduction in noise‐to‐diffusion contrast as compared with whole‐body performance (80 mT/m gradient amplitude, 200 T/m/sec gradient slew rate). </p><h3 class="article-section__sub-title section1"> Conclusion</h3><p>The PNS threshold of MAGNUS is significantly higher than that for whole‐body gradients, which allows for diffusion gradients with short rise times (under 1 msec), important for interrogating brain microstructure length scales.</p>
radiology, nuclear medicine & medical imaging
What problem does this paper attempt to address?