Experimental investigation of drumet-cut twisted tape inserts on performance enhancement of heat exchanger tube in turbulent flow
Kumar, Shivesh
DOI: https://doi.org/10.1007/s40430-024-04878-y
IF: 2.361
2024-04-25
Journal of the Brazilian Society of Mechanical Sciences and Engineering
Abstract:Twisted tape inserts significantly enhance the thermal performance of heat exchanger tube. A study of turbulent water flow through the tube fitted with drumet-cut twisted tape (DCTT) inserts has been conducted experimentally. The tube lateral surface is considered as the heat flux boundary condition. For water flow with different depth of cuts ( b = 4, 7, 10, and 13 mm) across Re ranging from 10,000 to 22,000, thermal performance (TP) and turbulent flow characteristics were examined. Due to the increased vortex fluid flow and flow stream caused by the DCTT geometry, there is better fluid mixing, which increases heat transfer. When comparing the Nusselt number (Nu), friction factor ( f ), and thermal performance ( η ) of the tube equipped with DCTT to the results of plain twisted tape, it is found that the Nu, f , and η of DCTT is increased by 3.35–13.82%, 5.62–26.80%, and 1.45–6.64%, respectively. Additionally, a comparison with existing work is made, and it is reported to perform superbly. Furthermore, the correlations for Nusselt number (Nu), the ratio of Nusselt number (Nu / Nu p ), friction factor ( f ), the ratio of friction factor ( f / f p ), and thermal performance ( η ) for DCTT inserts are also established and found that their deviations for the established correlations compared with experimental data are within ± 9%, ± 5%, ± 11%, ± 10%, and ± 4%, respectively.
engineering, mechanical