A novel spleen‐dedicated stiffness measurement by FibroScan® improves the screening of high‐risk oesophageal varices

Horia Stefanescu,Giovanni Marasco,Paul Calès,Mirella Fraquelli,Matteo Rosselli,Nathalie Ganne‐Carriè,Victor Ledinghen,Federico Ravaioli,Antonio Colecchia,Corina Rusu,Pietro Andreone,Giuseppe Mazzella,Davide Festi
DOI: https://doi.org/10.1111/liv.14228
IF: 8.754
2019-09-11
Liver International
Abstract:<h3 class="article-section__sub-title section1"> Background and Aims</h3><p>Several non‐invasive tests (NITs) have been developed to diagnose esophageal varices (EV), including the recent Baveno VI criteria to rule out high‐risk varices (HRV). Spleen stiffness measurement (SSM) with the standard FibroScan<sup>®</sup> (SSM@50Hz) has been evaluated. However, the EV grading could be underestimated due to a ceiling threshold (75 kPa) of the SSM@50Hz. The aims were to evaluate SSM by a novel spleen‐dedicated FibroScan<sup>®</sup> (SSM@100Hz) for EV diagnosis compared with SSM@50Hz, other validated NITs and Baveno VI criteria. </p><h3 class="article-section__sub-title section1"> Methods</h3><p>This prospective multicenter study consecutively enrolled patients with chronic liver disease; blood data, endoscopy, liver stiffness measurement (LSM), SSM@50Hz and SSM@100Hz were collected.</p><h3 class="article-section__sub-title section1"> Results</h3><p>Two‐hundred and sixty patients met inclusion criteria. SSM@100Hz success rate was significantly higher than that of SSM@50Hz (92.5% vs 76.0%, p&lt;0.001). SSM@100Hz accuracy for the presence of EV (AUC=0.728) and HRV (AUC=0.756) was higher than in other NITs. SSM@100Hz AUC for large EV (0.782) was higher than SSM@50Hz (0.720, p=0.027). AUC for HRV with SSM@100Hz (0.780) was higher than with LSM (0.615, p&lt;0.001). The spared endoscopy rate of Baveno VI criteria (8.1%) was significantly increased by the combination to SSM@50Hz (26.5%) or SSM@100Hz (38.9%, p&lt;0.001 vs others). The missed HRV rate was, respectively, 0% and 4.7% for combinations.</p><h3 class="article-section__sub-title section1"> Conclusions</h3><p>SSM@100Hz is a new performant non‐invasive marker for EV and HRV providing a higher accuracy than SSM@50Hz and other NITs. The combination of Baveno VI criteria and SSM@100Hz significantly increased the spared endoscopy rate compared to Baveno VI criteria alone or combined with SSM@50Hz.</p><p>This article is protected by copyright. All rights reserved.</p>
gastroenterology & hepatology
What problem does this paper attempt to address?