Coronary sinus blood flow estimated by transesophageal echocardiography correlates well with transit time flowmetry after coronary artery bypass grafting

A. Choudhury,S. Joshi,R. Magoon,M.P. Hote
DOI: https://doi.org/10.1053/j.jvca.2019.07.097
IF: 2.894
2019-09-01
Journal of Cardiothoracic and Vascular Anesthesia
Abstract:Introduction The adequacy of revascularisation is an important quality control measure of coronary artery bypass grafting (CABG). Intra-operative transit-time flowmetry (TTF) remains the most widely used technique for estimation of graft flow due to logistic issues of performing a completion angiography. Coronary sinus blood flow (CSBF) is often used for the assessment of the cardiac perfusion. Previous study have demonstrated the feasibility and reproducibility of transesophageal echocardiography (TEE) based non-invasive estimation of CSBF. [1] Due to paucity of literature, we planned to evaluate the predictive value of TEE based CSBF estimation for identifying favourable TTF graft measurements. Methods A Prospective observational study designed to include forty adult patients undergoing CABG after obtaining institute ethics committee approval. A TEE probe (Philips iE33, Bothell, WA, USA) was inserted after anaesthesia induction and the coronary sinus (CS) was imaged in the lower esophageal CS view at multi-planar angle of 0-10° and CS was centered in the imaging sector. A zoomed view was uitilised for measuring the CS diameter 1 cm before its opening into the right atrium. A pulsed wave Doppler was aligned (within 20° of angle correction) and applied with the sample volume well within the CS (approx. 1 cm inside).and the spectral signature was traced to get the VTI of CSBF. The acquisition was done 5 min after sternotomy when the haemodynamics returned close to the baseline values. The echo imaging and Doppler interrogations were done by an experienced echocardiographer who was unaware of patients’ diagnosis. After CABG, the surgeon applied TTF probes (Medistim VeriQ™ system, Oslo, Norway) to individual grafts for interrogation after ensuring the acoustic coupling index (ACI) >90% under sterile saline. Average graft pulsatility index (PI) and diastolic filling (DF) were noted with special attention to ACI>50% Before administering protamine, CSBF was estimated once again using the above technique after completion of CABG. Results The percentage increase in CSBF (δCSBF) was estimated by subtracting pre from the post CABG average CSBF values. Subjects were grouped based on favourable (PI <3, DF>50%) and unfavourable (PI>3, DF<50%) parameters. Group with PI<3 (n = 32) had significantly higher δCSBF compared to group with PI>3 (n = 8) (38.22±12.05%,13.75±3.37%, p<0.001). A strong negative and significantly positive correlation was observed between δCSBF with PI, DF (r = -0.903, 0.571 respectively, p<0.001). A δCSBF >19% was found to predict a mean PI<3 and DF>50% with sensitivity and specificity of 100% and 100%; 100% and 91.4% respectively. Discussion A TEE based demonstration of an augmented CSBF ensured favourable TTF graft parameters, guiding the adequacy of surgical revascularisation. It expands the horizon for application of TEE in the era of minimally invasive and endoscopic coronary artery bypass surgeries.
cardiac & cardiovascular systems,peripheral vascular disease,respiratory system,anesthesiology
What problem does this paper attempt to address?