Evolution of the morphology of filtering blebs through anterior segment OCT , one, three and six months after Preserflo Microshunt implant and its correlation with intraocular pressure
Gemma Ortega Prades,Vicente‐Tomás Pérez‐Torregrosa,Leyre Sanz Gallén,Álvaro‐Andrés Ojeda Parot,Prudencia Rochina Pérez,Antonio Miguel Duch Samper
DOI: https://doi.org/10.1111/aos.16201
2024-01-01
Acta Ophthalmologica
Abstract:Aims/Purpose: Study the evolution of the morphology of filtering blebs through AS‐OCT, one, three and six months after Preserflo implant and its correlation with IOP. Methods: Prospective observational study of 16 eyes with cataract and glaucoma, poorly controlled with maximum medical treatment and mean IOP of 23.6 mmHg, which underwent combined surgery with Preserflo and 0.04% MMC. The patients underwent measurement of IOP and AS‐OCT of conjunctival bleb one, three and six months after surgery. Bleb morphology is classified following the Leanzhofer classification as uniform or multiform (multilayer and/or multicystic). The presence of an episcleral aqueous lake in the distal part of the device is also studied. Results: Of the 16 patients studied, all completed the quarterly check‐up and 9 the six‐monthly check‐up. Of the total number of patients, 9 presented multiform multilayered bleb and 7 multiform multilayered with superficial cysts in the 1st and 3rd month. Of the 9 who completed the study up to the 6th month, 4 maintained their multilayered morphology, and of the remaining 5, who both in the 1st and 3rd month presented a multilayered morphology with superficial cysts, we observed a slight flattening of the bleb. The mean IOP in the 1st month was 12.5 mmHg, 12.6 in the 3rd month and 13.4 in the 6th month. Episcleral lake was observed in 9 cases, which remained present throughout the study. Conclusions: SA‐OCT is useful for monitoring conjunctival blebs after Preserflo implantation. Despite the slight thinning after the sixth month of the multiform multilayered blebs with superficial cysts, IOP remains stable. Therefore, the presence of multiform blebs and a maintained episcleral lake seem to be related to good hypotensive control. References 1. Lenzhofer M, Strohmaier C, Hohensinn M, Hitzl W, Sperl P, Gerner M, Steiner V, Moussa S, Krall E, Reitsamer HA. Longitudinal bleb morphology in anterior segment OCT after minimally invasive transscleral ab interno Glaucoma Gel Microstent implantation. Acta Ophthalmol 2019 Mar; 97(2): e231‐e237.
ophthalmology