Sigmoid Perforation by a Migrated Plastic Biliary Stent

Pedro Marcos,Gustavo Capelão,Catarina Atalaia-Martins,Paulo Clara,Liliana Eliseu,Helena Vasconcelos
DOI: https://doi.org/10.1159/000503076
2019-10-09
GE Portuguese Journal of Gastroenterology
Abstract:A 65-year-old female with a previous history of endoscopic retrograde cholangiopancreatography (ERCP) with stone extraction and placement of a straight biliary plastic stent (5 cm long and 10 Fr in diameter) due to residual choledocholithiasis presented with spontaneous distal migration of the stent in the scheduled ERCP 6 weeks later. The residual stones were removed. However, an abdominal X-ray to confirm the passage of the stent was not carried out. A subsequent laparoscopic cholecystectomy was uneventfully performed. Asymptomatic, 1 year later, the patient underwent a screening colonoscopy that revealed a foreign body suggestive of a plastic biliary stent, impacted in the sigmoid colon, in an area of diverticula (Fig. <a href="#f01">1</a>). The computed tomography showed a tubular structure compatible with the biliary stent perforating the sigmoid colon with both tips (Fig. <a href="#f02">2</a>). The CT scan did not reveal additional complications, and the patient remained asymptomatic. After multidisciplinary discussion, a surgical approach was proposed. The patient underwent an uneventful laparoscopic surgery with successful stent removal and closure of the perforations (Fig. <a href="#f03">3</a>).
What problem does this paper attempt to address?