X‐Ray‐Computed Radiography and Tomography Study of Electrolyte Invasion and Distribution inside Pristine and Heat‐Treated Carbon Felts for Redox Flow Batteries

Marcus Gebhard,Maike Schnucklake,André Hilger,Maximilian Röhe,Markus Osenberg,Ulrike Krewer,Ingo Manke,Christina Roth
DOI: https://doi.org/10.1002/ente.201901214
IF: 4.149
2019-11-11
Energy Technology
Abstract:<p>Porous carbon felts (CF) are a widely used electrode material for vanadium redox flow batteries (VRFB). These materials differ in their precursor material, thickness or graphitization degree and demonstrate broad differences in electrochemical performance. Prior to operation, an activation step, such as acid or heat treatment, is commonly performed to improve their performance. A thermal treatment in air functionalizes the surface of the electrode and improves reaction kinetics as well as the wettability of the electrode. In this work, pristine and heat‐treated carbon felts are compared regarding their electrolyte wetting behavior for the use in VRFB. Contact angle (CA) measurements were performed ex‐situ to investigate the effect of the heat treatment. Furthermore, the porous carbon felts were examined in‐situ with an in–house built flow cell regarding their invasion behavior with different types of electrolytes by X‐ray radiography. Additionally, the distribution of the electrolyte inside the felts was investigated by X‐ray tomography. The results demonstrate the effect of the heat treatment and choice of electrolyte on the wetting behavior and electrolyte distribution.</p><p>This article is protected by copyright. All rights reserved.</p>
energy & fuels
What problem does this paper attempt to address?