Whole-body diffusion-weighted imaging with background body signal suppression in the detection of osseous and extra-osseous metastases

Ahmed Abdel Razek,Ahmed Tawfik,Mariam Abdel Rahman,Saleh Teima,Ahmed Razek,Mariam Rahman
DOI: https://doi.org/10.5114/pjr.2019.90057
2019-01-01
Polish Journal of Radiology
Abstract:PURPOSE: To assess the reproducibility of detection of osseous and extra-osseous metastases in cancer patients using whole-body diffusion-weighted imaging with background body signal suppression (WB-DWIBS).MATERIAL AND METHODS: A prospective study was conducted on 39 consecutive patients (21 females, 18 males; mean age 48 years) with metastases, who underwent WB-DWIBS on a 1.5-T MR scanner. Image analysis was performed independently by two blinded observers. Inter-observer agreement was assessed for the detection of osseous (spinal, appendicular) and extra-osseous (hepatic, pulmonary, nodal, and peritoneal) metastases.RESULTS: The overall inter-observer agreement of WB-DWIBS in the detection of osseous and extra-osseous metastases was excellent (κ = 0.887, agreement = 94.44%, <i>p</i> = 0.001). There was excellent inter-observer agreement of both observers for the detection of osseous spinal (κ = 0.846, agreement = 92.3%), osseous appendicular (κ = 0.898, agreement = 94.8 %), hepatic (κ = 0.847, agreement = 92.3%), pulmonary (κ = 0.938, agreement = 97.4%), nodal metastases (κ = 0.856, agreement = 94.9%), and peritoneal metastasis (κ = 0.772, agreement = 94.9%).CONCLUSION: We concluded that WB-DWIBS is reproducible for detection of osseous and extra-osseous metastases in cancer patients.
What problem does this paper attempt to address?