P861 Immediate aortic dissection after transcatheter aortic valve replacement (TAVR)

P Rujirachun,A Junyavoraluk,D Jakrapanichakul,N Wongpraparut,N Chunhamaneewat,A Maneesai,P Sakiyalak
DOI: https://doi.org/10.1093/ehjci/jez319.506
2020-01-01
Abstract:Abstract Transcatheter aortic valve replacement (TAVR) is a treatment of choice for treating symptomatic severe aortic stenosis patient whose condition is considered the high and intermediate operative risk for surgical aortic valve replacement. Here, we present a case of 67-year-old man with symptomatic severe aortic stenosis, triple vessels disease, type 2 diabetes mellitus and end-stage renal disease who was treated with TAVR. After the valve was deployed, we found the abnormal leakage at descending aorta by transesophageal echocardiogram (TEE). Under intraoperative close monitoring, the dissection was slowly expanding so we decided to perform thoracic endovascular repair (TEVAR). In conclusion, TEE after TAVR procedure is helpful to detect this rare complication. Reported cases of AD status post TAVR Author Sex/Age Comorbidity Detection time of AD Site of AD Detection of AD Treatment for AD Result Route access of TAVR This case 2018 M/67 DM, ESRD Immediate after implant Ds TEE TEVAR Recovery Femoral Losmanova et al. 2018 F/81 NA 3 yrs As Autopsy Conservative Died NR Kratimenos et al. 2016 F/81 COPD, renal dysfunction, angiodysplasia 12 days Ds CT TEVAR Recovery Femoral Nagasawa et al. 2016 F/86 Heart failure During the procedure Ds TEE Conservative Recovery Femoral Yashima et al. 2015(14) F/88 NA 3 days As CT Conservative Recovery Femoral Van Mieghem et al. 2013 F/86 Coronary artery disease, post total knee prosthesis 1-2 hours As Angiogram TEVAR Recovery Femoral Loeser et al. 2013 F/89 NA 2-5 hours As Autopsy NA Cardiogenic shock and died Femoral Bibombe et al. 2013 M/83 Previous CBG, HT, DLP During the procedure As and Ds TEE, CTA, angiogram Open surgery Recovery Femoral Al-Attar et al. 2013 F/84 HT, thrombophlebitis 8 months 2 weeks As CT Open surgery Arrest and died Femoral D"Onofrio et al. 2012 F/79 RA, pulmonary edema, cerebral hemorrhage Immediate after implant As TEE Open surgery Died 32 day later due to septic shock Aortic Ong et al. 2011 M/90 HT, CA prostate, CKD, gastric and duodenal ulcer Immediate after implant As TEE Conservative Recovery Femoral Gerber et al. 2010 F/83 DM, LE 22 days As Autopsy NA Cardiac arrest and died Femoral Abbreviations M Male; F Female; DM Diabetes mellitus; ESRD End-stage renal disease; NA Not available; COPD Chronic obstructive pulmonary disease; CBG Coronary bypass graft; HT hypertension; DLP Dyslipidemia; RA Rheumatoid arthritis; CA cancer; CKD Chronic kidney disease; LE Lupus erythematosus; AD Aortic dissection; As Ascending; Ds Descending; TEVAR Thoracic endovascular aortic repair. Abstract P861 Figure. Intraoperative TEE after TAVR
What problem does this paper attempt to address?
The problem that this paper attempts to solve is the occurrence of aortic dissection (AD) immediately after transcatheter aortic valve replacement (TAVR). By reporting a specific case, the paper explores the occurrence mechanism, diagnostic methods and treatment measures of this rare complication. Specifically, the patient in the paper was a 67 - year - old male, suffering from severe aortic stenosis, three - vessel coronary artery disease, type 2 diabetes and end - stage renal disease. After TAVR surgery, abnormal leakage in the descending aorta was detected by transesophageal echocardiography (TEE), and the dissection gradually expanded under close intraoperative monitoring. Eventually, thoracic endovascular aortic repair (TEVAR) was adopted to treat this complication. The paper also summarizes reports of other similar cases to compare the situations of different patients, the time of complication occurrence, detection methods, treatment methods and results, further emphasizing the importance of using TEE after surgery, especially in terms of timely detecting and handling this rare but potentially fatal complication.