Assessment of Global and Regional Lung Compliance in Pulmonary Fibrosis with Hyperpolarized Gas MRI.
Ming Zhang,Haidong Li,Yi Xiao,Hongchuang Li,Xiaoling Liu,Xiuchao Zhao,Yu Zheng,Yeqing Han,Fumin Guo,Xianping Sun,Jianping Zhao,Shiyuan Liu,Xin Zhou
DOI: https://doi.org/10.1002/jmri.29497
IF: 4.4
2024-01-01
Journal of Magnetic Resonance Imaging
Abstract:Background: Lung compliance, a biomarker of pulmonary fibrosis, is generally measured globally. Hyperpolarized Xe-129 gas MRI offers the potential to evaluate lung compliance regionally, allowing for visualization of changes in lung compliance associated with fibrosis. Purpose: To assess global and regional lung compliance in a rat model of pulmonary fibrosis using hyperpolarized Xe-129 gas MRI. Study Type: Prospective. Animal Model: Twenty Sprague-Dawley male rats with bleomycin-induced fibrosis model (N = 10) and saline-treated controls (N = 10). Field Strength/Sequence: 7-T, fast low-angle shot (FLASH) sequence. Assessment: Lung compliance was determined by fitting lung volumes derived from segmented Xe-129 MRI with an iterative selection method, to corresponding airway pressures. Similarly, lung compliance was obtained with computed tomography for cross-validation. Direction-dependencies of lung compliance were characterized by regional lung compliance ratios (R) in different directions. Pulmonary function tests (PFTs) and histological analysis were used to validate the pulmonary fibrosis model and assess its correlation with Xe-129 lung compliance. Statistical Tests: Shapiro-Wilk tests, unpaired and paired t-tests, Mann-Whitney U and Wilcoxon signed-rank tests, and Pearson correlation coefficients. P < 0.05 was considered statistically significant. Results: For the entire lung, the global and regional lung compliance measured with Xe-129 gas MRI showed significant differences between the groups, and correlated with the global lung compliance measured using PFTs (global: r = 0.891; regional: r = 0.873). Additionally, for the control group, significant difference was found in mean regional compliance between areas, eg, 0.37 (0.32, 0.39) x 10(-4) mL/cm H2O and 0.47 (0.41, 0.56) x 10(-4) mL/cm H2O for apical and basal lung, respectively. The apical-basal direction R was 1.12 +/- 0.09 and 1.35 +/- 0.13 for fibrosis and control groups, respectively, indicating a significant difference. Data Conclusion: Our findings demonstrate the feasibility of using hyperpolarized gas MRI to assess regional lung compliance.