Kamlet–Taft Dipolarity/Polarizability of Binary Mixtures of Supercritical Carbon Dioxide with Cosolvents: Measurement, Prediction, and Applications in Separation Processes

Alif Duereh,Yuta Sugimoto,Masaki Ota,Yoshiyuki Sato,Hiroshi Inomata
DOI: https://doi.org/10.1021/acs.iecr.0c01251
2020-06-09
Abstract:A flow-type apparatus and predictive framework were developed for measuring and estimating dipolarity/polarizability (π*) values of binary mixtures of supercritical carbon dioxide (scCO<sub>2</sub>)–cosolvents. The π* values of scCO<sub>2</sub> with methanol and ethanol cosolvents (up to 10 mol %) are reported at the temperature ranging from 40 to 80 °C and pressure ranging from 10 to 20 MPa and were found to be dependent on fluid density. The predictive framework for scCO<sub>2</sub>–cosolvent mixtures proposed in this work was the modification by the addition of correction functions (<i>g</i>(ρ<sub>CO<sub>2</sub></sub>)) of local density enhancement into the previous predictive framework for binary liquid nonpolar–polar mixtures [ <i>Ind. Eng. Chem. Res.</i> <span class="NLM_year">2019</span>, <em>58</em>, 18986−18996]. Four <i>g</i>(ρ<sub>CO<sub>2</sub></sub>) forms with a function of CO<sub>2</sub> density were evaluated by considering literature local density enhancements of pure CO<sub>2</sub> obtained from (i) fluorescence, (ii) Raman, (ii) UV–vis spectroscopic techniques, and (iv) molecular dynamics simulations. The framework was applied to the prediction of π* of four scCO<sub>2</sub>–cosolvent mixtures (methanol, ethanol, 2-propanol, and 1,1,1,2-tetrafluoroethane (HFC134a)) and was found to give a reliable value with an overall relative deviation of 0.03 between the experimental and calculated data, where the fluorescence <i>g</i>(ρ<sub>CO<sub>2</sub></sub>) function provided a lower deviation than the other three functions. The application of the framework to separation processes showed that the π* values were found to explain the trends of solubility, extraction yield, and fractionation recovery. The π* values determined from the framework can be used to analyze solvent effect trends in many separation processes that required only cosolvent dipole moment, pure π* component, and CO<sub>2</sub> density (pressure and temperature).The Supporting Information is available free of charge at <a class="ext-link" href="/doi/10.1021/acs.iecr.0c01251?goto=supporting-info">https://pubs.acs.org/doi/10.1021/acs.iecr.0c01251</a>.<i>P</i>–<i>X</i>–<i>Y</i> diagram of CO<sub>2</sub>–cosolvent mixtures (Figures S1–S3); correction functions for density enhancement (Figures S4–S7); experimental maximum absorption wavelength of indicators and Kamlet–Taft dipolarity/polarizability of pure solvents and solvent mixtures (Tables S1–S7); comparison of experimental maximum absorption wavelength of indicators and Kamlet–Taft dipolarity/polarizability of pure solvents and solvent mixtures between this work and the literature (Figures S8–S13); cybotactic region of the indicator (Figure S14); prediction results of mixed-solvent systems (Figures S15–S29); parity plots and deviation plot (Figures S30 and S31); comparison result in average relative deviation (Tables S8); information of cosolvent dipole moment, π* values of pure components and CO<sub>2</sub> density (Tables S9); relationship of Kamlet–Taft dipolarity/polarizability with applications in extraction, fractionation and solubility (Figures S32–S40) (<a class="ext-link" href="/doi/suppl/10.1021/acs.iecr.0c01251/suppl_file/ie0c01251_si_001.pdf">PDF</a>)This article has not yet been cited by other publications.
engineering, chemical
What problem does this paper attempt to address?