In situ grown TiO2 nanorod arrays functionalized by molecularly imprinted polymers for salicylic acid recognition and detection

Xiuxiu Xiong,Chao Li,Xiaoyu Yang,Yun Shu,Dangqin Jin,Yang Zang,Yusheng Shu,Qin Xu,Xiao-Ya Hu
DOI: https://doi.org/10.1016/j.jelechem.2020.114394
IF: 4.598
2020-09-01
Journal of Electroanalytical Chemistry
Abstract:<p>Salicylic acid (SA) is the active agent in a great many analgesics and anti-inflammatory drugs. Its abuse would result in side effects to the health of human beings. Developing a simple and effective method for real-time tracking and monitoring of SA is necessary. In this work, a novel electrochemical sensor based on the molecularly imprinted polymers functionalized TiO<sub>2</sub> nanorod arrays modified fluorine doped tin oxide (FTO) glass electrode (MIPs/TiO<sub>2</sub> ) was fabricated for the detection of salicylic acid (SA). TiO<sub>2</sub> NRAs were directly grown on FTO by a simple hydrothermal method. SA was imprinted on TiO<sub>2</sub> through a facile UV polymerization process. The nanorods structure of TiO<sub>2</sub> provided a high specific surface area for SA imprinting, raising the number of imprinted sites, minimizing diffusion limitations, improving the internal mass transport, enhancing accessibility of the active sites and consequently boosting the sensitivity and binding capacity of the sensor. Furthermore, TiO<sub>2</sub> could act as a photosensitizer in the presence of AIBN initiator to promote the formation of MIPs via a simple photo-polymerization process. The electrodes were characterized by scanning electron microscopy (SEM) and X-ray diffraction spectroscopy (XRD). Cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were used to demonstrate the electrochemical sensor construction process. The differential pulse voltammetry (DPV) signal of the MIPs accumulated SA exhibited the linearity to its concentration ranging from 1.0 × 10<sup>−7</sup> to 5.0 × 10<sup>−5</sup> M under the optimized conditions. The detection limit was down to 3.9 × 10<sup>−8</sup> M based on S/N = 3. This sensor has been applied for the detection of SA in the Aspirin tablet successfully. The results showed that this MIPs/TiO<sub>2</sub> electrochemical sensor could be applied in medical field simply with low-cost. This work may provide new insights into the design and fabrication of a new platform for sensing applications.</p>
chemistry, analytical,electrochemistry
What problem does this paper attempt to address?