Lead-polyester resin composite as an alternative material for radiation protection in radiography

I Yulianti,Susilo,Masturi,T Susanti,R Setiawan
DOI: https://doi.org/10.1088/1742-6596/1567/3/032069
2020-06-01
Journal of Physics: Conference Series
Abstract:Abstract This work presents synthesization and characterization of polyester resin doped with lead acetate (Pb (CH 3 COO) 2 ) as an alternative material for radiation protection in radiography. Five samples were synthesized with various lead concentration which are 0%, 3.5%, 3.75%, 4% and 4.5%. The samples were characterized using X-ray, He-Ne laser, and FTIR. The results showed that as lead concentration was increased, optical density increased while X-ray transmission decreased. It were found that the attenuation coefficients for each samples were 0.132 cm −1 , 0.435 cm −1 , 0.543 cm −1 , 0.691 cm −1 , and 1.156 cm −1 . In terms of transmission and attenuation coefficient, lead-polyester composite with lead concentration of 3.5% has an optimum performance.
What problem does this paper attempt to address?