Measurement of stapes footplate thickness in otosclerosis by ultra-high-resolution computed tomography

Yukinori Akazawa,Akira Ganaha,Teruyuki Higa,Shunsuke Kondo,Yoshiki Oyakawa,Hitoshi Hirakawa,Mikio Suzuki,Tsuneo Yamashiro
DOI: https://doi.org/10.1080/00016489.2020.1788225
2020-07-23
Abstract:<span>Ultra-high-resolution computed tomography (U-HRCT) utilizes a 1024 × 1024 matrix with 0.25-mm section thickness, offering better spatial resolution than conventional multi-detector row CT to detect anatomic data for otologic surgery.We examined stapes footplate thickness using U-HRCT in relation to stapedotomy to predict the difficulty of the surgical procedure.Subjects were 12 otosclerosis patients and 25 controls who underwent diagnostic U-HRCT. A profile curve (Hounsfield units) was used to measure stapes footplate thickness along a perpendicular line across the stapes footplate in a plane parallel to the lateral semicircular canal.Footplate thickness was smaller at the midpoint than just before the anterior crus and just after the posterior crus. Interobserver variability was lowest at the midpoint, where foot plate thickness was significantly greater in the affected ear in otosclerosis patients compared with controls (0.60 ± 0.09 mm vs 0.46 ± 0.04 mm; <i>p</i> &lt; .001). Otosclerosis patients were detected using U-HRCT with a high area under the curve. Difficulty in the stapes opening procedure correlated with stapes footplate thickness.Footplate thickness on U-HRCT correlated with temporal bone anatomy and corresponded to surgical difficulty. <b>Significance:</b> U-HRCT-derived anatomic data is useful for evaluating the stapes.</span>
otorhinolaryngology
What problem does this paper attempt to address?