Common body temperature sites provide invalid measures of body core temperature in hyperthermic humans wearing American football uniforms

Kevin C. Miller,William M. Adams
DOI: https://doi.org/10.1080/23328940.2020.1829940
2020-10-15
Temperature
Abstract:<span>Valid body core temperature measurements are essential for diagnosing and monitoring athletes with exertional heat stroke (EHS). Experts question the validity of body temperature sites that vary by &gt;±0.27°C from the gold standard, rectal temperature (T<sub>REC</sub>). No research has established the validity of body temperature sites when American football uniforms (PADS) are worn during simulated EHS scenarios. Thirteen men (age, 22 ± 2 y; mass, 77.5 ± 8.8 kg; height, 181.3 ± 5.7 cm) donned PADS and entered an environmental chamber (38.7 ± 0.8°C, 38.9 ± 2.4% relative humidity). We compared T<sub>REC</sub> to a forehead liquid crystal temperature monitor (T<sub>FHD</sub>), axillary (T<sub>AXL</sub>), oral (T<sub>ORL</sub>), and aural temperatures (T<sub>EAR</sub>) 34 times over four consecutive periods: 10-minutes of rest; exercise until participants T<sub>REC</sub> was between 39.7°C and 39.8°C; cold-water immersion (CWI, 10.0 ± 0.1°C) until all temperature sites indicated ≤38°C; and a 15-minute post-immersion recovery period. Body temperatures varied between sites during all periods (F<sub>36,432</sub> ≥ 2.5, <i>P</i> ≤ 0.001). T<sub>AXL</sub> and T<sub>ORL</sub> statistically differed from T<sub>REC</sub> and exceeded the 0.27°C bias threshold at all 34 measurement times (100%). T<sub>FHD</sub> differed from T<sub>REC</sub> eight times during rest; eight times during exercise; 0 times during CWI; and twice during recovery (18/34, 53%). T<sub>FHD</sub> exceeded the bias threshold 28 times (82%). T<sub>EAR</sub> differed from T<sub>REC</sub> five times during rest; 0 times during exercise; five times during CWI; and once during recovery (11/34, 32%). T<sub>EAR</sub> exceeded the 0.27°C bias threshold 15 times during testing (44%). T<sub>AXL</sub>, T<sub>FHD</sub>, T<sub>EAR</sub>, and T<sub>ORL</sub> should not be used to diagnose or monitor American football players with EHS. <b>Abbreviations ANOVA:</b> analysis of variance; CWI: cold water immersion; EHS: exertional heatstroke; PADS: full American football uniform consisting of a helmet; shoulder, knee, thigh, hip and tailbone pads; a jersey top; undergarments; and half-length pants; T<sub>AXL</sub>: axillary temperature; T<sub>EAR</sub>: aural temperature; T<sub>FHD</sub>: liquid crystal temperature monitor; T<sub>ORL</sub>: oral temperature; T<sub>REC</sub>: rectal temperature</span>
What problem does this paper attempt to address?