Robust polymer electrolyte membrane fuel cell temperature tracking control based on cascade internal model control

Fengxiang Chen,Jieran Jiao,Zhongjun Hou,Wei Cheng,Jun Cai,Zenggang Xia,Jie Chen
DOI: https://doi.org/10.1016/j.jpowsour.2020.229008
IF: 9.2
2020-12-01
Journal of Power Sources
Abstract:To optimize fuel cell system efficiency, compared with the regulation control of temperature, the latest engineering practice is more inclined to perform tracking control. The fuel cell temperature subsystem has the characteristics of slow response and strong nonlinearity, which poses challenges to tracking control. This paper proposes a cascade internal model control (CIMC) to make the stack outlet temperature track the target value when fuel cell load currents changes. Both simulation and experiment show that the control method has good rapidity, accuracy and robustness. The Simulation results based on AMESIM® shows that the step response static errors of static points test and step signal test are all 0 °C. The response time of step signal test is around 47s. Both of the step response and dynamic response the overshooting are 0 °C without divergence. The experiment results on a real 120 kW commercial fuel cell system test bench are similar with the simulation results with 0 °C static error at different working conditions, 44s response time for step response and overshooting around 1 °C at the dynamic working condition, which is acceptable for the tested PEMFC stack.
energy & fuels,materials science, multidisciplinary,electrochemistry,chemistry, physical
What problem does this paper attempt to address?