Evaluation of thermoanalytical methods equipped with evolved gas analysis for the detection of microplastic in environmental samples

C. Goedecke,D. Dittmann,P. Eisentraut,Y. Wiesner,B. Schartel,P. Klack,U. Braun
DOI: https://doi.org/10.1016/j.jaap.2020.104961
IF: 6
2020-11-01
Journal of Analytical and Applied Pyrolysis
Abstract:Microplastic particles are currently detected in almost all environmental compartments. The results of detection vary widely, as a multitude of very different methods are used with very different requirements for analytical validity.In this work four thermoanalytical methods are compared and their advantages and limitations are discussed. One of them is thermal extraction-desorption gas chromatography mass spectrometry (TED-GC/MS), an analysis method for microplastic detection that has become established in recent years. In addition, thermogravimetric analysis coupled with Fourier-transform infrared spectroscopy (TGA-FTIR) and mass spectrometry (TGA-MS) were applied, two methods that are less common in this field but are still used in other research areas. Finally, microscale combustion calorimeter (MCC) was applied, a method not yet used for microplastic detection.The presented results are taken from a recently published interlaboratory comparison test by Becker et al. (2020). Here a reference material consisting of suspended matter and specified added polymer masses was examined, and only the results of the recoveries were presented. In the present paper, however, the results for the individual polymers are discussed in detail and individual perspectives for all instruments are shown.It was found that TED-GC/MS is the most suitable method for samples with unknown matrix and unknown, variable kinds and contents of microplastic. TGA-FTIR is a robust method for samples with known matrix and with defined kinds of microplastic. TGA-MS may offer a solution for the detection of PVC particles in the future. MCC can be used as a very fast and simple screening method for the identification of a potential microplastic load of standard polymers in unknown samples.
engineering, chemical,chemistry, analytical,energy & fuels
What problem does this paper attempt to address?
The problem that this paper attempts to solve is to clinically distinguish unilateral breast edema caused by congestive heart failure (CHF) from inflammatory breast cancer (IBC). Specifically, the paper discusses the case of an elderly female patient who had unilateral breast edema due to congestive heart failure and was initially clinically suspected of having inflammatory breast cancer. However, no definite mass was found through imaging examinations, and after standard heart failure treatment was adopted, the breast edema was alleviated. Therefore, the paper emphasizes the importance of considering congestive heart failure as a possible cause of unilateral breast edema during the diagnosis process, especially when the patient has a history of heart failure, in order to avoid unnecessary examinations and treatments and reduce medical costs and patient suffering. The paper also reviews relevant literature, summarizes reports of similar cases, and discusses various possible causes of unilateral breast edema, including malignant conditions (such as inflammatory breast cancer, lymphoma, leukemia, etc.) and benign conditions (such as mastitis, granulomatous diseases, post - surgical changes, post - radiotherapy changes, lymphatic obstruction, etc.). In addition, the paper points out that although systemic diseases (such as congestive heart failure) usually lead to bilateral edema, unilateral breast edema may also occur in some cases, especially when the patient tends to lie on one side, which may lead to edema on the dependent side. In summary, the main purpose of this paper is to raise doctors' awareness that congestive heart failure may cause unilateral breast edema, so that more accurate diagnoses can be made when encountering patients with similar symptoms.