Optic Nerve Sheath Diameter for Predicting Outcomes in Post-Cardiac Arrest Syndrome: An Updated Systematic Review and Meta-Analysis

Jae-Guk Kim,Wonhee Kim,Hyungoo Shin,Tae-Ho Lim,Bo-Hyoung Jang,Youngsuk Cho,Kyu-Sun Choi,Min-Kyun Na,Chiwon Ahn,Juncheol Lee
DOI: https://doi.org/10.3390/jpm12030500
IF: 3.5083
2022-03-20
Journal of Personalized Medicine
Abstract:We aimed to identify the efficacy of optic nerve sheath diameter (ONSD) in predicting mortality and poor neurological outcomes (PNO) in post-cardiac arrest syndrome (PCAS) by the measurement time of outcomes. We conducted an extensive literature search in EMBASE, MEDLINE, and Cochrane Library, which included studies on the prognostic accuracy of ONSD in predicting PNO and mortality in PCAS by the measured time of outcomes. A total of 791 patients from nine studies were included. Increased ONSD was weakly associated with PNO by a high heterogeneity (standardized mean difference with 95% confidence interval = 0.74 (0.22, 1.27); I2 = 87%). The analysis by the measurement time of PNO and mortality for ONSD had no significant difference due to insufficient articles or high heterogeneities. The prognostic accuracy of ONSD was 23.97 (pooled diagnostic odds ratio, I2 = 0%) and 0.94 (area under the curve) for short-term PNO. The pooled results showed low or very low quality and very low quality of evidence for PNO and mortality, respectively. ONSD measurement might be an effective predictor for short-term PNO in PCAS. An analysis by measurement time of outcomes showed no significant evidence for ONSD measurement effectiveness in predicting mortality and PNO.
medicine, general & internal,health care sciences & services
What problem does this paper attempt to address?